Inverted angle steel, unequal angle steel, angle channel and i-beam
Descriptions
As a plank-shaped pile used in civil engineering and construction work, it is also called a sheet pile. It prevents the ground from collapsing around or from the ceiling when digging the foundations and tunnels. It is also used as a cofferdam for drainage in underwater construction.
Dimensions and Sectional Properties
Section | Standard Sectional Dimension (mm) |
Sectional Area (cm2) |
Unit Weight (kg/m) |
Moment of Inertia (cm4) |
Modulus of Section (cm3) |
||||||
---|---|---|---|---|---|---|---|---|---|---|---|
B | H | t | Per Pile (cm2) |
Per Wall Width (cm2/m) |
Per Pile (kg/m) |
Per Wall Width (kg/m2) |
Per Pile (cm4) |
Per Wall Width (cm4/m) |
Per Pile (cm3) |
Per Wall Width (cm3/m) |
|
SP-Ⅱ | 400 | 100 | 10.5 | 61.2 | 153.0 | 48.0 | 120 | 1,240 | 8,740 | 152 | 874 |
SP-Ⅲ | 400 | 125 | 13.0 | 76.4 | 191.0 | 60.0 | 150 | 2,220 | 16,800 | 223 | 1,340 |
SP-ⅢA(D) | 400 | 150 | 13.0 | 76.4 | 191.0 | 60.0 | 150 | 3,060 | 22,600 | 278 | 1,510 |
SP-Ⅳ | 400 | 170 | 15.5 | 96.9 | 242.5 | 76.1 | 190 | 4,670 | 38,600 | 362 | 2,270 |
SP-ⅤA | 500 | 200 | 24.3 | 133.8 | 267.6 | 105.0 | 210 | 7,960 | 63,000 | 520 | 3,150 |
SP-ⅡW | 600 | 130 | 10.3 | 78.7 | 131.2 | 61.8 | 103 | 2,110 | 13,000 | 203 | 1,000 |
SP-ⅢW | 600 | 180 | 13.,4 | 103.9 | 173.2 | 81.6 | 136 | 5,220 | 32,400 | 376 | 1,800 |
SP-ⅣW | 600 | 210 | 18.0 | 135.3 | 225.5 | 106.0 | 177 | 8,630 | 56,700 | 539 | 2,700 |