Electric electronic apparatus for Vessel & Industrial plant facility, Solar module manufacturing development
Motor Controller SMC-500 Series
Type Approval : ABS, BV, GL, KR, LR
2/3 stand-by start
2 speed reversible start
2 speed start
reversible start
constant start (auto/manual, remote/local, y-d start)
The motor controllers of SMC-500 SERIES are multi-functional high-performance products that are to be easily used wherever the Motor Operating is needed. These Series satisfy the various international standards and adopt the standardized circuits and the control circuits are composed of international standardized parts selected rigidly.
As special features, the exterior materials have high insulation level, light weight, fire retardant, shock resistant and chemical resistant characteristics to endure the harsh environment such as shipyard, power plant, steelworks, petrochemical complex and water power plant etc.. These have IP65 grade.
ORDERING INFORMATION
ELECTRICAL AND MECHANICAL SPECIFICATIONS
INPUT POWER SOURCE | RATING | AC 22V 50 / 60Hz | |
VARIATION | CONTINUOUS :AC 22V ±10% | MAXIMUM : AC 22V ±20% | |
SURGE TRANSIENT | 2kV 50uVs line / earth : 1kV 50uVs line / line [IEC 1000-4-5/1995] | ||
POWER CONSUMPTION | 20VA [MAX.]---Inside Control Fuse : 250Vac 2A [miniature glass tube] | ||
TIMER SPECIFICATION Controlled by digital circuit] | ACCURACY [Ta : ambient temperature] | less than ± 1% [-10℃ < Ta < +45℃] less than ± 5% [-20℃ < Ta < -10℃, +45℃ < Ta < +55℃] | |
RATING OF PUSH BUTTON FOR START, STOP | 250Vac, 3A [p.f=0.4], [-25℃ < Ta < +55℃] -Life Expectancy:Mechanical life - 1,000,000 cycles Electrical life - 100,000 cycles | ||
RATING OF SELECTOR SWITCH FOR AUTO / MANUAL, HEATER | 250Vac, 3A [p.f=0.4], [-25℃ < Ta < +55℃] - Life Expectancy : Mechanical life 250,000 cycles Electrical life - 100,000 cycles | ||
RATING OF EXTERNAL T.B FOR CONNECTION | 600V / 15A[-30℃ < Ta < +105℃], 1000V / 9A [-30℃ < Ta < + 105℃] | ||
RATING OF CONTROL RELAY FOR ELECTROMAGNETIC CONTACTOR | APPLICATION CIRCUIT | | |
LIFE EXPECTANCY | Mechanical life - 30,000,000 cycles / Electrical life - 100,000 cycles | ||
SIGNAL OUTPUT [250Vac 0.3A : p.f=0.4] | Stand-by, stand-by started [5sec.], Overload, Low pressure, Power fail, Abnormal stop, CPU fail | ||
ELECTRICAL INSULATION RESISTANCE | Above 200㏁ between live part and enclosure | ||
DIELECTRIC STRENGTH | 2.5kVac, 1min between 88 control line [P1, P2, P3,P4, P5] and enclosure |