Dual Channel Flow/Level/Temperature Flow - Model VS 5100 Full-featured VERSA Switch ®
Mail Feature
Simple field configurable unit for mass flow, level, and/or temperature of liquids or gasses with time delay adjustable from 0 to 300 sec.
Wide operating temperature range -100°F to +850°F (-70°C to +458°C).
Field selectable operating power 110VAC, 220VAC, or 24VDC.
Removable, plug in electronics.
Can be configured with 2 independent outputs, such as level or mass flow with temperature or two mass flow rates
Can be used for either gas or liquid applications including interface detection.
Self heating sensor design. No separate heater to establish thermal differential
Two Year Workmanship Warranty.
Specification
Sensor
Type: Thermal Differential, dual RTD sensors with no seperate heater
Process Connection: Standard 0.75 inch MNPT Optionally 0.25 inch and larger NPT and various other process connections such as sanitary and flanges
Insertion Length: Standard 2.0 inch Optionally 0.5 inch or greater
Operating Temperature Range: Standard -100°F to 390°F (-70°C to +200°C) Medium Temperature to +572°F (+300°C) High Temperature to +850°F (+458°C)
Materials of Construction: Standard 316L Series Stainless Steel Optionally Hastelloy, Monel, Inconel and other exotic materials
Operating Pressure Range: Standard to 3000 psia (207 bar)
Electronics
Power: Standard Field selectable 110VAC, 220VAC, or 24VDC at 3 watts (No heater power required) Optionally 24VAC
Operating Temperature Range: Standard -40°F to +140°F (-40°C to +60°C) Optionally: Remote electronics for use in higher temperature environments.
Outputs: Independent primary relay DPDT and secondary relay SPDT, contacts rated at 5 amp, 250 VAC with fail safe capability; built in time delay 0 to 300 seconds for each channel.
Self-Test: Integral and automatic during power up.
Failure Alarm Option: Continuous monitoring circuit to alarm should a failure condition of any sensor, component, wiring, or power occur. (Uses second channel of the VS5100)
Enclosure: Explosion proof; NEMA 3, 4, 4x,7, and 9; CSA, FM, UL,CENELEC, and EECS approved
Instrument
Operating Range: Flow 0.01 to 5.0 fps in oil,2.5 fps in water and 0.1 to 500fps in gases. Level change as small as .03 inch. Temperature -70° C to +458° C +/- 1° C.
Response Time: Media dependent 0.5 to 10 seconds.
Approvals: CSA Class 1 Div. 1 Groups B,C,&D Class 2 Div. 1 E,F,&G with T4A Temp rating.
M & C Engineering, Inc. is a established in 1999.
Since the company's inception, we have worked continuously to supply instruments and flow meters of various and notable manufacturers.
We are also leading sales representative company which is specialized in flowmeter in Korea and our staffs have been working on this business more than 15 years in Korea.
We,therefore, are known in korea market very well.
Based on our marketing goal and combined with the manufacturer's high standard of technology, manufacturing, quality, delivery, etc.
We will always look out from our customer's perspective so that we may be the most reliable partner who always exceeds the expectations of our customers.
We will always look out from our customer's perspective so that we may be the most reliable partner who always exceeds the expectations of our customers.