Application
For exhaust gas of engine & Boiler steam and high temperature flow object.
Vibration-resistant and shock-resistant position at high temperature.
Features
1. High accuracy
2. Rapid response time
3. High durability against vibration.
4. Easy maintenance.
5. Replaceable internal element at fitting status
Standard Model of Thermocouple
MODEL | Operating Range (℃) | Material of Protecting well | Remark |
TCA-D | 0~600℃ | SUS304 | With Amplifier & Compensation or Extension Cable |
- MCA-D must be used with amplifier and compensation or extension cable
L | ØD1 | ØDo/D | S | e |
80, 100, 120, 150 | 12 | 23/17 | Standard : PF 3/4 Option : PF 1/2, M33, M20 etc | 25 |
180, 200, 250, 300 | 15 | 23/20 | ||
Above 300 | 15 | 22 |
* Operating Range : 0 ~ 600℃ -TCA-S : without protecting well
Tolerance of Thermocouple (Type K)
Operating Temperture (℃) | Class | Toleranc (℃) |
-40~375 | 1 | ±1.5 |
375~1000 | ±0.004 ㅣtㅣ | |
-40~333 | 2 | ±2.5 |
333~1200 | ±0.075ㅣtㅣ |
TCA-D(type 2)
Application
Use for Cylinder Liner
Features
1. Excellent measurement Accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy.
- Operating Range : 0~600℃
- CLASS : 2
TCA-D(type 3)
Application
Use for Cylinder Liner
Features
1. Excellent measurement Accuracy
2. Rapid response speed.
3. High durability against vibrations.
4. Maintenance and checks are easy.
- Operating Range : 0~600℃
- CLASS : 2