Service intended
P980 series explosion proof indicating pressure switches measure a corrosive fluid and a high pressure. It is equipped with a micro contact or an electrical contact block, which is suitable for all types of contacts.
Nominal diameter |
100 mm |
Accuracy |
Indicator : ±1.0 % of full scale Alarm setting : ±3.0 % of full scale |
Repeatability |
±1.0 % of adjustable range (Micro contact type) |
Adjustable range (MPa, kPa, bar) |
-0.1 ~ 0 to 0 ~ 2 MPa 0 ~ 0.1 to 0 ~ 35 MPa |
Working temperature |
Ambient : -20 ~ 65 °C Fluid : Max. 100 °C |
Temperature effect |
Accuracy at temperature above and below the reference temperature (20 °C) will be effected by approximately ±0.4 % per 10 °C of full scale |
Standard features
Pressure connection |
Stainless steel (316SS) |
Element |
C type bourdon tube Stainless steel (316SS) |
Case and cover |
ALDC12.1 Silver gray painted aluminium Surface mounting |
Contact |
■ Micro contact One SPDT or Two SPDT ■ Electrical contact One SPST or Two SPST |
Contact rating |
■ Micro contact type AC 125 V, 5 A / 250 V, 3 A and DC 30 V, 4 A DC 125 V, 0.4 A for resistance load AC 125 V, 3 A / 250 V, 2 A and DC 30 V, 3 A DC 125 V, 0.05 A for inductive load ■ Electrical contact AC 250 V, 1.0 A |
Conduit connection |
½" NPT(F), Lead wire length (Max. 1 m) * Refer to "Swtiching element" for wiring diagram. |
Process connection |
⅜", ½" PT, NPT and PF Setpoint adjustment |
Certificates |
KCS Ex d IIC T6 |
Option |
Explosion proof type cable gland ● 304SS ● ½" NPT(M) |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.