Service intended
P621 to P622 series are designed to measure differential pressure from 30 kPa ro 1.5 MPa at Max. working pressure up to 5 MPa.P621 to P622 series are designed to control and alarm for differential pressure, providing right time to replace air and sluge filter during the process.
Nominal diameter |
150 mm |
Accuracy |
±1.0% of full scale ±1.5% or ±1.6% of full scale |
Scale range (MPa, kPa, bar) |
0~30 kPa to 0~50 kPa 0~0.1 MPa to 0~1.5 MPa |
Max. Working pressure (Static pressure) |
5 MPa |
Working temperature |
Ambient : -20~65°C Fluid : Max. 100°C |
Degree of protection |
EN60529/IEC529/IP56 |
Temperature effect |
Accuracy at temperature above and below the reference temperature (20℃) will be effected by approximately ±0.5% per 10℃ of full scale |
Standard features
Pressure connection |
Stainless steel (316SS) |
Element |
Single Bellows Stainless steel (316L SS) |
Case |
Black finished aluminium |
Cover |
Black finished aluminium Screwed type |
Window |
Glass |
Dial |
White aluminium with black graduations |
Conduit connection |
M20 x 1.5P |
Contact |
Contact rating: AC 250 V 3 A / 125 V 5 A DC 250 V 0.2 A / 125 V 0.4 A / 30 V 4 A Dielectric strength: AC 500 V / MIN Type: Micro contact, One and two SPDT |
Pointer |
Black painted aluminium alloy |
Process connection |
¼" NPT(F) ½" NPT(F) at 3-way and 5-way manifold valve |
Standard accessories |
Mounting bracket for 2" pipe mounting with silver gray finished steel |
Optional |
- Remote seal
- Mounting bracket with 316SS for 2" pipe mounting
- 3-way manifold valve (316SS, Monel)