Orifice flange assembly is used in conjunction with orifice plate for flow measurement of smaller or medium size pipes at lower or medium pressure ranges. The flange connection is a RF type and the differential pressure tapping system is the flange taps.
Specification
Flange mounting type |
Welding neck Slip-on Socket-weld Ring-joint welding neck |
Nominal diameter |
25 ~ 600 mm 1" ~ 24" |
Flange ratings |
JIS 10, 20, 30, 40 and 63 K ANSI (or JPI) 150, 300, 600, 900, 1500 and 2500Lb RF |
Flange material |
A105, A182-F304, A182-F316, A182-F11, A182-F22, A350-LF2 and Other |
Materials of bolts and nuts |
Stud blots : SNB7, A193-B7 and A194-B8 and Other Nuts : S45C, A194-2H and A194-8 and Other Jack bolts : 304SS |
Gasket |
Thickness : 4.5 mm Material : Spiral wound gaskets |
Differential pressure piping connection |
Select referring to the model number construction table |
Orifice bore type |
Concentric square edged orifice Quadrant edged orifice Eccentric orifice Segmental orifice |
Flow claculation standards |
ISO 5167-1 and 2 2003 AGA-3 ASME MFC-3M (R.W Miller) JIS Z 8762 |
Plate thickness |
3,6,9,12 mm and Over |
Plate material |
Standard : 304SS and 316L SS Non-standard : Monel, Hastelloy B/C, Titanium etc. |
Drain and vent hole |
Per ASME recommendations Not drilled for orifice bores smaller than 25.4 mm |
Markings |
Upstream side of tab handle stamped "Upstream" and with bore type and size, line size, tag number and flange rating |
Special markings |
Special marking may be furnished to meet special requirement |