Water Chiller, Heat Pump, Portable Air Conditioner, Temperature & Humidity Chamber, Heat Exchanger and more
HEAT PUMP
High-efficiency system capable of air conditioning and heating with one piece of equipment by releasing indoor heat into the atmosphere without a separate cooling tower and it is heated using the heat absorbed from the atmosphere when heating.
Produce stable high-temperature water by binary cycle method, Extending system life by built-in safety devices, Saving money on fuel cost
CHARACTERISTIC
- It operates to normal without auxiliary heat source in cold weather, 20 degrees below zero
- The heat pump life is expended sharply with built-un perfect safety devices
- It is composed of special material(inside) and paint(outside) not to rust
- By applying anti-vibration device and noise control device, it can be use it conveniently
-It can be check and control all operation conditions with monitor at counter, main room or convenient place
BINARY CYCLE
Existing Binary Heat pump
The refrigeration standard cycle plays a refrigeration role by repeating and circulating with 4 processes, [compression process → condensation process → expansion process → evaporation process] In case of use it in 4seasons, it’s occurred big problem on evapration process because of calorie deficiency for outdoor air in winter season. Namely, In cold winter season, the refrigerant inhales to compressor in not to evaporate completely because of calorie deficiency.
Binary Heat Pump(Patent Cycle)
The binary cycle method is using 2 kinds refrigerant which has good absorbing capacity of heat energy R410A and excellent production abliity of high temperature water R-134a.
FLOW DIAGRAM
STANDARD SPECIFICATION
Item | DHB-15 | DHB-20 | DHB-30 | DHS-20 | DHS-10 | DH-05HG | |
---|---|---|---|---|---|---|---|
Performance | Type | Binary-Cycle | Fam-house facilities | Geothermal-Cylce | |||
Heating capacity(Kcal/h) | 60,000 | 77,000 | 110,000 | 60,000 | 30,000 | 19,800 | |
Heat Storage tank temp.(℃) | 70-75 | 70-75 | 70-75 | 55-60 | 55-60 | 55-60 | |
Water outlet temp.(℃) | 75-80 | 75-80 | 75-80 | 60-65 | 60-65 | 60-65 | |
Hot water Flow rate (kg/min) | 165 | 220 | 330 | 200 | 100 | 58 | |
Cold capacity(Kcal/h) | 42,000 | 56,000 | 70,000 | 56,000 | 28,000 | 21,500 | |
Compressor | Type | Scroll | |||||
Heating Power Consumption(Kw/h) | 30 | 40 | 55 | 20 | 10 | 6.3 | |
Cooling Power Consumption(Kw/h) | 15 | 20 | 25 | 20 | 10 | 5.7 | |
Fan motor | Standard(Φ x Kw x P x EA) | 700 x 0.75 x 6 x 2 | 600 x 0.4 x 6 x 3 | 750 x 0.75 x 8 x 3 | 600 x 0.4 x 6 x 3 | 600 x 0.4 x 6 x 2 | X |
CMM | 400 | 500 | 750 | 500 | 300 | X | |
Water pipe | In / Out | 40A | 50A | 65A | 50A | 32A | 25A |
Dimension | L x W x H (mm) | 2,070 x 1,000 x 1,775 | 2,630 x 900 x 1,775 | 3,230 x 1,100 x 2,055 | 2,630 x 900 x 1,775 | 1,770 x 900 x 1,720 | 605 x 780 x 875 |
Refrigerant | R134A/R410a | R134A/R410a | R134A/R410a | R-407c | R-407c | R-410a | |
Control of refrigerant (expansion valve type) | Electronic | ||||||
Main Power | 3PH 4-wire 380V 60Hz | ||||||
For safety | Negative-phase detection, Over current relay, High & Low pressure switch, Protection of compressor overheat, Freeze protection, Flow switch |
※Period
1. Heating Capacity can be changed depend on area in winter season.
2. Power consumption on heting & cooling is maximum power consumption.
3. Geothermy heating capacity : load / heat source inlet Temp. 40℃/5℃, Cooling capacity : load / heat source inlet Temp. 12℃/25℃
PURPOSE OF USE
Bathing Facilities/Accommodation Facilities
Agricultural Facilities/Religious Facilities
For Public Facilities