Water Chiller, Heat Pump, Portable Air Conditioner, Temperature & Humidity Chamber, Heat Exchanger and more
GEOTHEMAL SOURCE
With Using heat energy it has soil, underground water and surface water, it cools by exporting indoor high temperature to underground in summer season. and, it is heating system by absorbing heat from
underground in winter season. Alternative energy facilities capable of operating costs saving for air-conditioning and heating.
CHARACTERISTIC
- Application for expansion & reduction of machinery room which is unnecessary cooling tower, outdoor unit
- Cheap operating cost with ground heat source
- Supply eco-friendly system by using eco-friendly refrigernt(R-410A)
- Patent technology for self-production
- Hot water/Heating/Cooling with one equipment
- Suitable product for installation obligation business according to certificate of renewable energy equipment
Geothemal Source Heat Pump
With one equipment to Hot water / Heating / Cooling and Floor-heating!
It is available to heating, hot-water, cooling and floor heating with ine equipment and has cost saving effect.
FLOW DIAGRAM
STANDARD SPECIFICATION
Item | DH-05HG | |
---|---|---|
Performance | System type | Geothermal-Cycle |
Heating capacity(Kw) | 18 | |
Heating capacity(Kcal/h) | 15,500 | |
Heat Storage tank temp.(℃) | 50-60 | |
Water outlet temp.(℃) | 55-70 | |
Hot water Flow rate (kg/min) | 58 | |
Cold capacity(Kcal/h) | 14,800 | |
Compressor | Type | Scroll |
Heating Power Consumption(Kw/h) | 5 | |
Cooling Power Consumption(Kw/h) | 4 | |
Fan motor | Standard (Φ x Kw x P x EA) | 402 |
Water pipe | In / Out | 25A |
Dimension | L x W x H (mm) | 600 x 800 x 800 |
Refrigerant | R-410a | |
Control of refrigerant (expansion valve type) | Electronic | |
Main Power | 3PH 4-wire 380V 60Hz | |
For safety | Negative-phase detection, Over current relay, High & Low pressure switch, Protection of compressor overheat, Freeze protection, Flow switch |
※Period
1. Heating capacity : It can be changed depend on outside condition
2. Standard of cooling capacity : Outdoor temperature 35℃, Outlet Temp. 7℃, Inlet Temp.12℃
3. Standard of heating power consumption : Outdoor temperature 7℃, Inlet Temp. 40℃ Outlet Temp. 45℃ Geothermal heating capacity : Load/Heat source Inlet Temp. 40℃/5℃, Cooling capacity : Load/Heat source Inlet Temp. 12℃/25℃
* All the details can be changed without any notice with the products developed
PURPOSE OF USE
Bathing Facilities/Accommodation Facilities
Agricultural Facilities/Religious Facilities
For Public Facilities