Dust collector manufacturer, Environmental equipment, Air pollution prevention facility and more
Features
Vacuum cleaner attached type in the certain workplace where vacuum cleaning is necessary
Filter Type
Bag Filter, Cartridge Filter
Application
Mixing work, powder dumping work, sanding work, bagging work, metal processing work, etc.
Specifications-APV Series (AP+VM-120)
Product Specifications
TYPE | Air volume(CMM) | static pressure(mmAq) | output(Kw) | size | weight(kg) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
A width | B length | C height | D total width | E total length | F total height | G inlet(Ø) | H outlet(Ø) | |||||
AP-100 | 12 | 230 | 0.75 | 520 | 520 | 1369 | 648 | 542 | 1527 | 150 | 200 | 135 |
AP-200 | 30 | 230 | 1.5 | 620 | 620 | 1480 | 748 | 642 | 1652 | 200 | 250 | 190 |
AP-200/629 | 6.2 | 3300 | 3.7 | 620 | 620 | 1510 | 748 | 639 | 1713 | 65 | 125 | 210 |
AP-300 | 40 | 230 | 2.2 | 770 | 770 | 1555 | 898 | 795 | 1759 | 250 | 300 | 310 |
AP-500 | 65 | 230 | 3.7 | 850 | 770 | 1605 | 978 | 795 | 1809 | 250 | 300 | 390 |
AP-750 | 80 | 250 | 5.5 | 910 | 830 | 1965 | 1072 | 855 | 2169 | 300 | 350 | 780 |
AP-829 | 75 | 2500 | 8.6 | 720 | 645 | 1855 | 925 | 695 | 2000 | 63 | 100 | 350 |
AP-1000 | 100 | 250 | 7.5 | 1370 | 850 | 1970 | 1522 | 875 | 2174 | 350 | 400 | 920 |
AP-1500 | 150 | 250 | 5.5X2SET | 1750 | 900 | 1970 | 1912 | 925 | 2189 | 400 | 450 | 980 |
AP-2000 | 200 | 250 | 7.5X2SET | 1950 | 1000 | 2045 | 2112 | 1025 | 2310 | 500 | 550 | 1080 |
AP-3000 | 300 | 260 | 11X2SET | 1980 | 1250 | 2250 | 2142 | 1275 | 2479 | 600 | 650 | 1150 |
Product name | power supply | output | vacuum degree | filter | specifications |
---|---|---|---|---|---|
VM-120 | 220V/1P(50Hz/60Hz) | 1,200W 1, 6HP | 24,0KPa | POSYESTER | Ø150X200L |
Power and Filter Specifications
TYPE | Power | filter | ||
---|---|---|---|---|
60Hz(Premium),50Hz | size | quantity | type | |
AP-100 | 220V 1P, 220V / 380V 3P 60Hz 440V(Option), 50Hz(Option) |
145X500L | 4 | General(PET) water repellent coating flame retardant aluminum antistatic NOMEX PTFE(membrane) |
AP-200 | 6 | |||
AP-300 | 220V / 380V 3P 60Hz 440V(Option), 50Hz(Option) |
9 | ||
AP-500 | 12 | |||
AP-750 | 145X800L | 12 | ||
AP-829 | 145X500L | 16 | ||
AP-1000 | 145X800L | 18 | ||
AP-1500 | 24 | |||
AP-2000 | 165X800L | 24 | ||
AP-3000 | 32 |
- Filter size : 145Ø, 165Ø (옵션)
※ This specification may change without notice for performance improvement.
Filter
API SERIES Filter Information
· Equipped with cartridge filter, it has wide filtration area and it is easy to replace by integrating with cell plate.
· The material is PET, membrane, Nomex, etc., and water-repellent antistatic (aluminum) treatment is applied according to the purpose.
Water repellence Prevents water invasion but lets air permeation |
|
Flame retardance Fire does not spread well |
|
Antistatic(aluminum) Superb antistatica |
|
Membrane Filtration efficiency of 0.3 fine dust is 99.9%, no fine dust emission |
|
Membrane Filter
|
Characteristics of PTFE ㆍHeat and cold resistance: 150 degrees of usage temperature ㆍChemical resistance: Inert to acid, alkali, etc. ㆍElectrical features: high insulation, high frequency ㆍNon-adhesive, combustion resistant |
Efficient Filter Cleaning
① Filter by cleaning in assigned differential pressure value
② Adjusting settings according to site situation
③ Automated cleaning by assigned cycle even after dust collector operation stops
Controller
The digital controller that puts your convenience as its number one priority
• Applied color LCD and soft touch switch
• Interface: Adopted standard mode to enable linked operation with external contacts
• Error Report: Displaying error alarm and alarm history when error occurs
• Digital differential pressure, digital current, operation integration, error status indicator function
• Dedicated Inverter Controller: Manual/Auto control of inverter
Specifications-MSV Series(MS+VM-120)
Product Specifications
TYPE | Air volume(CMM) | static pressure(mmAq) | output(Kw) | size | weight(kg) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
A width | B length | C height | D total width | E total length | F total height | G inlet(Ø) | H outlet(Ø) | |||||
MS-50 | 7 | 210 | 0.55 | 450 | 520 | 755 | 724 | 542 | 883 | 100 | 125 | 50 |
MS-100 | 12 | 230 | 0.75 | 520 | 520 | 1260 | 817 | 539 | 1452 | 150 | 150 | 100 |
MS-200 | 30 | 230 | 1.5 | 620 | 620 | 1370 | 943.3 | 642 | 1563 | 200 | 200 | 120 |
MS-300 | 40 | 230 | 2.2 | 750 | 750 | 1532 | 1086 | 792 | 1724 | 250 | 300 | 180 |
MS-500 | 65 | 230 | 3.7 | 770 | 770 | 1581 | 1086 | 792 | 1774 | 250 | 300 | 185 |
MS-750 | 80 | 250 | 5.5 | 1200 | 750 | 1742 | 1404 | 876 | 1950 | 300 | 350 | 340 |
MS-1000 | 100 | 250 | 3.7X2SET | 1500 | 750 | 1587 | 2062 | 985 | 1720 | 350 | 400 | 440 |
MS-1500 | 150 | 250 | 5.5X2SET | 1800 | 950 | 1715 | 2432 | 1035 | 1976 | 400 | 450 | 485 |
Product name | power supply | output | vacuum degree | filter | specifications |
---|---|---|---|---|---|
VM-120 | 220V/1P(50Hz/60Hz) | 1,200W 1, 6HP | 24,0KPa | POSYESTER | Ø150X200L |
Power and Filter Specifications
TYPE | Power | filter | |||
---|---|---|---|---|---|
60Hz(Premium),50Hz | size | quantity | type | ||
MS-50 | 220V 1P, 220V / 380V 3P 440V(Option), 50Hz(Option) |
220V / 380V 3P 60Hz 440V(Option), 50Hz(Option) |
420X200 | 8 | General antistatic water repellent cotton cloth NOMEX |
MS-100 | 420X600 | 7 | |||
MS-200 | 14 | ||||
MS-300 | 640X650 | 15 | |||
MS-500 | 20 | ||||
MS-750 | 30 | ||||
MS-1000 | 40 | ||||
MS-1500 | 50 |
※ This specification may change without notice for performance improvement.
Filter
MSV SERIES Filter Information
· Maximized efficiency by installing flat square pocket type filter.
· Various filters suitable for dust characteristics can be installed (antistatic water repellent, cotton cloth)
· Integrated structure for easy filter replacement.
Water repellent Prevents water invasion but lets air permeation |
Cotton cloth Collects elevated dust |
Antistatic Excellent antistatic function |
Efficient Filter Cleaning
Manual (Hand Shaking)
Shaking handles are shaken to remove dust, and dusting is more effective in detaching dust when the fan is stopped.
Automatic (Motor Shaking)
The differential pressure is measured according to the filter contamination condition and the shaking motor starts automatically after the fan operation to shake off the dust.
Controller
The digital controller that puts your convenience as its number one priority
• DIGITAL CONTROL PANEL: LED touch switch and color LCD screen
• Digital Differential Pressure Measurement Control: Displays digital differential pressure value and graph
• Digital Ammeter Function: Checks the operation status by displaying the real-time current value on the digital screen
• Error Alarm System in Case of Error: Displays alarm history and error details
• Automatic Motor Shaking Function: Detects the differential pressure and efficiently executes the filter dusting
• Digital Control Panel: Soft LED touch switch method
• Built-in External Operation (Remote/Interlocking) Control Function: Changing basic terminal block and one-touch setting
APV/MSV common
TURBO BLOWER Information
In-house turbo fan production for the most efficient performance management system
High air volume |
high wind pressure |
low vibration |
low noise |
Accessories
Hose/Inlet |
Filter |
Nozzle |
Detachable Iron Net |
Crevice Tool |
Round Brush |
Pipe |