TOP
Dust collector manufacturer, Environmental equipment, Air pollution prevention facility and more
Features
Dust collector for removing odor using a large amount of activated carbon (hazardous gas purification)
Filter Type
Activated Carbon
Application
Volatile organic compounds and gas (VOC), NOx and SOx (optional), adsorption contaminants: H2S, SO2, CH3SH, NO3, slight livestock odors, chemical factories
Specifications
Product Specifications
TYPE | Air volume(CMM) | static pressure(mmAq) | output(Kw) | activated carbon amount(kg) | size | weight(kg) | |||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
A width | B length | C height | D total width | E total length | F total height | G inlet(Ø) | H outlet(Ø) | ||||||
ACT-100 | 12 | 230 | 0.75 | 150 | 1200 | 800 | 1565 | 1500 | 1115 | 1565 | 150 | 200 | 380 |
ACT-200 | 25 | 230 | 1.5 | 240 | 1350 | 900 | 1920 | 1615 | 1215 | 1920 | 200 | 250 | 550 |
ACT-300 | 40 | 230 | 2.2 | 450 | 1350 | 1300 | 2155 | 1750 | 1615 | 2155 | 250 | 300 | 900 |
ACT-500 | 60 | 230 | 3.7 | 650 | 1350 | 1300 | 2510 | 1750 | 1615 | 2510 | 250 | 300 | 1150 |
ACT-750 | 80 | 250 | 5.5 | 900 | 1600 | 1526 | 2507 | 2090 | 1815 | 2507 | 300 | 350 | 1550 |
ACT-1000 | 100 | 250 | 7.5 | 1000 | 1700 | 1500 | 2750 | 2245 | 1815 | 2750 | 350 | 400 | 1650 |
Power and Filter Specifcations
TYPE | Power | filter | ||
---|---|---|---|---|
60Hz(Premium),50Hz | activated carbon amount | type | ||
ACT-100 | 220V 1P, 200V / 380 3P AC 60HZ /440V(OPTION) 50HZ(OPTION) |
150 | Granular Activated Carbon | |
ACT-200 | 240 | |||
ACT-300 | 220V / 380V 3P AC 60HZ /440V(OPTION) 50HZ(OPTION) |
450 | ||
ACT-500 | 650 | |||
ACT-750 | 900 | |||
ACT-1000 | 1000 |
※ This specification may change without notice for performance improvement.
Features
Adsorption tower is a device that absorbs and removes various organic gas and odor and is a facility that adsorbs gas where strong absorption force of bonding of atoms on solid surface composed of molecular layers and chemical bonding of gas only
Low maintenance fee Operation is simple and maintenance cost is low due to recycled use of activated carbon |
Strong adsorption Activated carbon used as adsorbent is very effective for adsorbing organic vapor. |
Wide range of adsorption It can absorb a wide range of solvents with low boiling point. |
Enhanced space utilization The installation space is small compared to the throughput because the residing time for adsorption is small. |
Maximum efficiency of collection The recovery rate of organic gas (98%) is outstanding. |
Controller
The digital controller that puts your convenience as its number one priority
• Digital Control Panel: Soft LED touch switch method
• Built-in External Operation (Remote/Interlocking) Control Function: Changing basic terminal block and one-touch setting