Circuit breaker automatic testing equipment (ACB, VCB, RTSG) manufacturer, energy harvesting and digital gamma counters
Main Function
- Measures the bus bar’s temperature in real time and wirelessly sends the temperature data.
- 20 temperature sensors can simultaneously measure and send data
- Procures power through Energy Harvesting method
Features of Equipment
ㆍPC (desktop computer) or laptop as receiver
ㆍData Receiver
ㆍData Sender
ㆍTemperature measuring sensors and power device that uses energy harvesting
– Measures 30℃ ~ 170℃
– Uses low-energy equipment
– Bus bar collects electric power, partially stores electric power, and utilizes the device
Assessment Detector Types
ㆍScintillator Detector
Scintillator | NaI(Tl), 1.5″ x 1.5″ (Dia. x L) |
Size | 63 ㎜ x 166 ㎜ (Dia. x L) |
Operating Temperature | -30 ∼ 175 ℃ |
Humidity | 7-100% (Non-condensable) |
Input Voltage | DC 500 ∼ 1500 V |
Gamma-ray Energy Range | 0.08 ∼ 3 MeV |
Measurement Range | 3.7E-2 ∼ 3.7E+3 Bq/cc |
Accuracy and Linearity | ± 15% |
Usage | Environmental radiation detection and measurement |
ㆍIon Detector
Size | 63 ㎜ x 310 ㎜ (Dia. x L) |
Operating Temperature | -17 ∼ 50 ℃ |
Humidity | 7 ∼ 100% (Non-condensable) |
Input Voltage | DC 1400 V, 2200 V |
Gamma-ray Energy Range | 0.05 ∼ 3 MeV |
Measurement Range | 1.0E-3 ∼ 1.0E+3 [mSv/h] |
Accuracy and Linearity | ± 15% |
Usage | Environmental radiation detection and measurement |
ㆍGM Detector
Size | 63 ㎜ x 184 ㎜ (Dia. x L) |
Operating Temperature | -17 ∼ 50 ℃ |
Humidity | 7-100% (Non-condensable) |
Input Voltage | DC 500 V |
Gamma-ray Energy Range | 0.05 ∼ 3 MeV |
Measurement Range | 1.0E-4 ∼ 1.0E+5 [mSv/h] |
Accuracy and Linearity | ± 15% |
Usage | Environmental radiation detection and measurement |