Industrial automatic control machine manufacturer, Control switch, Limit switch, Hoist switch and more
Features
1. Battery replacement cycle increasing by designing a low effort.
2. Streamlined shape design and miniaturization transmitter.
3. Applying strong nylon glass on impact for enhanced reliability.
4. Providing convenience to apply a mode selector switch.
5. MSIP-CRM-KGO-KG-R12MLHCCC
MSIP-CRM-KGO-KG-R08AAA
Performance
List | Transmitter | Receiver |
Frequency range | 447.6000 ~ 447.9875 Mhz | 447.6000 ~ 447.9875 Mhz |
Rated Voltage | 08R : DC3V / 12R : DC6V | 90C ~ 240V AC /50 ~ 60 Hz |
Size | 08R : 150mm X 52mm X 41mm 12R : 230mm X 56mm X 49mm | 08R / 12R : 230mm X 56mm X 70mm |
Electric Power antenna | 10mW | 10mW |
Oscillation method | PLL | PLL |
Modulation system | GFSK(F1D) | GFSK(F1D) |
Method of communications | Simplex | Simplex |
Transmission speed | 2400bps | 2400bps |
Frequency stability | 2ppm 이하 | 2ppm 이하 |
Channel number | 32ch | 32ch |
Channel separation | 12.5khz | 12.5khz |
Bandwidth | 8.5khz 이하 | 8.5khz이하 |
Usual temperature | -20℃ ~ +60℃이하 | -20℃ ~ +60℃이하 |
Cable | K60227 IEC7 300/500V 0.75SQ 16/23C (1.7M) | |
Transmitting distance | No obstacle 130M | No obstacle 130M |
REMOTE CONTROLLER
Model | KG-R08 SERIES | KG-R12 SERIES |
Function | ㆍE-STOP ㆍSelector ON/OFF switch ㆍ ㆍBattery : AA1.5V 2ea | ㆍE-STOP ㆍSelector ON/OFF switch ㆍ ㆍMode selection function Selector switch AUX-MAIN, LIGHT, A A+B B ㆍButton : F1(HORN), F2 ㆍBattery : AA1.5V 4ea |
Product Function
Receiver ▶ KG-R12P MODEL | Transmitter ▶ KG-R08P MODEL |
Name composition
External form / Drawing
KG-R08AAA / KG-R08AAA(D)
KG-R08AAA(T)
KG-R12MLHAAA
Accessory
KG-R200
| KG-R300 / R400 Transmitter shock protection guard | G-R500 / R600 Transmitter vinyl cover |
Connection diagram
KG-R08(D) 12/24V DC
KG-R08 110/220V AC
KG-R12 SERIES
KG-R08(T) SERIES (Remocon & pendant connection diagram)
Basic Used And Precautions
1. Turn off the emergency switch.
2. Turn the green selector switch on the bottom of the transmitter turned ON by pressing any button will power ON.
If the receiver can be operated lamp lighting completed.
3. Press the any button for operation
4. After use, the bottom of the green selector switch on the transmitter left OFF when stored.
5. If the battery power indicator lights up on the cases(BAT), replace the electrical (AA 1.5V).
(If not in use should be kept as an emergency switch OFF, you can prevent battery discharge.)
Safety information
Before using this product, Please read the safety information.
Danger
1. Be sure to turn off power before connection wires or changing bulb, it can cause electric shock.
2. Product installation can be sure only qualified personnel precautions. according to a safety precautions.
Warring
1. Please check for the correct connection wire before installing it. Incorrect wiring will cause a break down of product.
2. Please check for the correct voltage, Over voltage will cause by malfunction of product.
Caution
1. This product is only suitable for indoor use.
2. Applying a strong shock on the outside of product may cause break down.
3. Please refer to the "wiring diagram" when you wire the product.
4. Please be cautions that contact with chemical such as thinner or benzene can cause of deformation of the product or color of change.
5. The contents of this manual may be changed without prior notification.