Air leak tester, He leak tester, Leak, Flow, Pressure test equipment
M1035 Mass Flow Leak Detector
A versatile and user friendly solution to production line test problems
Products Imformaiton
● UNIQUE FEATURES
- Versatile
ㆍMeasures leaks in the range of 0 to 20 sccm.
ㆍPart volumes in excess of 15 liters can be tested.
ㆍTest pressure is adjustable to 100 psig.
- User Friendly
ㆍOnly three settings are required to run to test:
Accept / reject level
Test Pressure
Fill-Bypass-Stabilize-Test-Times
ㆍVacuum fluorescent display and test parameters, results and statistics.
ㆍUp to 99 different test routines are available for instant recall.
ㆍBuild in diagnostics simplify troubleshooting.
- Accurate
ㆍ0.05 sccm transducer repeatability.
ㆍTest results are insensitive to line pressure variations.
- Automatic
ㆍNo operator judgement is required.
ㆍPanel displays indicate test status and results.
- Fail Safe
ㆍFault light warns of out of specification test conditions.
ㆍTransducer operates in a self-check mode.
ㆍSeal check feature monitors fixture integrity.
- SPC Compatible
ㆍLast 1,000 test results are stored, with their statistics for analysis and downloading to IBM compatible PC.
- Other Features
ㆍIsolated contact interface.
ㆍRS-232C and parallel printer ports.
● SPECIFICATIONS
Enclosure : 8.25" H x 21" W x 15.75" D
Temperature Range : 32º F - 115º F
Display : 80 Characters, 4 x 20 vacuum fluorescent
Viewing Door : (Optional) Lockable
Keyboard : (Optional) 101 key detachable
HARDWARE FEATURES - One Test Channel SOFTWARE FEATURES
Inputs : Start Test
Reset
Test Program Select (99 max.)
Outputs : 4 Output relays
Accept/Reject/Test-in- Progress/Trouble
Isolated contact (each contact rated
250V, 60Hz, 3 Amps)
Parallel printer port
ELECTRICAL
Supply Voltage : 110 V, 60 Hz, 1 Amp (Standard)
Switchable for 220V, 50/60 Hz
CONTROLS
Power Switch : On / Off switch
Key Touchpad : 20 alpha-numeric
PERFORMANCE
A/D Conversion : 12 Bit (Standard)
Test Method : Mass Flow
Leak Range : 0 - 20 sccm (Standard)
Test Pressure Range : 0 - 100 psig
TRANSDUCER
Leak Range : 0 - 10 sccm (Standard Reservoir)
Repeatability : 0.01 sccm (Full Scale)
Sensitivity : 0.005 sccm (Full Scale)
Response Time : 0.7 seconds
Operating System : MS DOS based
Test Capabilities : 99 test programs
Test Parameters : Fill/Bypass/Stabilize/Test Time
Min/Max Pressure Limits
Upper Accept/Reject level
Lower Accept/Reject level
Calibration Value
Data Storage : Last 1,000 test records
(date/time/station#/part#/test
value/test status)
Total counts (by part)
Statistics : All statistics apply to last 1,000 tests or
tests since last count reset or part
change.
Mean, Std. Deviation, ± 3 Std. Deviation
Displays : Screen menus (user friendly)
Normal test mode display
Seal check display
Calibration display
Data display (test pressure, leak rate)
Part parameters
Utility functions
Select part display
Password enter display
System diagnostics display