The Aliamag AMC2100E series converter is a microprocessor based intelligent transmitter that can be paired with any of the Alia AMF series sensors. The unit features multiple display parameters including flow rate, flow total, diagnostics, programming and troubleshooting.

AMC2100E series converter with temperature / energy.

 

Feature

  • Four line LCD display Flow Rate / Energy / Totalizer
  • Accuracy of +/-0.4% of reading
  • Bi-directional flow measurement, current and pulse output
  • Large digital display, with temperature / energy function
  • 99 times records for power on / off
  • MODBUS/HART communication

 

 

Specification

Excitation:                                                              Keyboard:
DC pulsed                                                                 4 external keys for programming 
Display:                                                                  and display control
4 lines LCD with back light                                         Low Flow Cutoff:
Line 1                                                                     0 to 9.9 %
Date and Time                                                          Data logger Function:
Line 2                                                                     99times flowrate records for power on/off
6 digit flowrate                                                         Record Data:
7 digit energy value                                                  Date/Time when power on/off
Fault code                                                                99 years flow rate / energy /
Supply temperature                                                  temperature / total flow / total energy
Line 3                                                                     One record data per Hour
9 digit totalizer for forward / reverse flow                   Damping:
9 digit totalizer for heat / cold  energy                        0.1 to 99.9 seconds
Fault code content                                                    Self Diagnosis:
Return temperature                                                  The following error message are
Line 4                                                                     displayed if failure occurs
Differential temperature                                            - Coil failure
Unit                                                                        - Power failure
L/S, L/M, L/H, M3/S, M3/m, M3/H, ML/H, ML/m           - Overanged Output 
ML/S, KW, MW, KJ/H, MJ/H, GJ/H, Mcal/H
Kcal/H, Cal/H                                                           - Internal error
Measuring Range:                                                 - Overflow
Min.  0 to 0.15 m/s                                                  - Empty pipe
Max. 0 to 15 m/s                                                     Cable Entry:
Accuracy:                                                              Standard :PG11 Option:1/2"NPTF
+/-0.4% of reading (Velocity >=0.5 m/s)                  Protection Class:
+/-0.002 m/s (Velocity < 0.5 m/s)                            IP 65
Repeatability:                                                       Ambient Temperature:
+/-0.1% of reading                                                 -25 to +65 ℃
Current Output:                                                    Material:
4-20 mA (Isolated)                                                  Aluminum Alloy
Load                                                                     Temperature Input:
Max. 600                                                               PT1000W, 2 wire 
Pulse output:                                                       Power Supply:
Open collector                                                        90-260 VAC, 50/60 Hz
Rating                                                                  24 VDC +/- 10% (Option)
3 to 30 VDC, 20 mA Max.                                        Power Consumption:
Pulse Rate:                                                          3-17 W (Dependent on sensor size)
1)Scale pulse (Pusle/M3, Pulse/L, Other)                  Weight:
2)Frequency: 0-5000 Hz                                         1.4 Kg
Communication:                                                  Mounting:
RS 485 (MODBUS Protocol)                                     Wall mounting
HART signal (Compatible)                                       Bracket on 2" pipe
Data Storage: 
Operation parameters and totalizer  
figures are stored by EEPROM for more 
than 10 years

M&C ENGINEERING
유량계 및 각종 계기 전문업
M & C Engineering, Inc. is a established in 1999. Since the company's inception, we have worked continuously to supply instruments and flow meters of various and notable manufacturers. We are also leading sales representative company which is specialized in flowmeter in Korea and our staffs have been working on this business more than 15 years in Korea. We,therefore, are known in korea market very well. Based on our marketing goal and combined with the manufacturer's high standard of technology, manufacturing, quality, delivery, etc. We will always look out from our customer's perspective so that we may be the most reliable partner who always exceeds the expectations of our customers. We will always look out from our customer's perspective so that we may be the most reliable partner who always exceeds the expectations of our customers.