product Image
Magnetic Flowmeter – ALIA
Model Name
AMC3200E Series
Series
전자기유량계
Data
Catalog-M&C Engineering-Magnetic Flowmeter – ALIA-AMC3200E Series
Manufacturer information
provider logo
M&C ENGINEERING

유량계 및 각종 계기 전문업

Problem with product info?
Update request
Manufacturer
M&C ENGINEERING
Brand
-
SKU
139867
Product Name
Magnetic Flowmeter – ALIA
Model Name
AMC3200E Series
Size
-
Weight
-
Product Details

AMC3200E series is a heat meter converter of electromagnetic flowmeter that can be paired with any of ALIA AMF series sensors. The unit features multiple display parameters including flow rate, energy, flow total, energy total, supply temperature, return temperature, diagnostic, programming and troubleshooting. It's equipped with Modbus, Bluetooth and BACnet protocol.

 

Features

  • Four line LCD display Flow Rate/ Energy/ Totalizer/ Temperature
  • +/-0.2% value of reading
  • Bi-direction flow measurement, and the display can rotate
  • With hourly report, daily report, monthly report and yearly report query function
  • 99 times/dates records for alarm
  • 99 (total) times records for power on/ off
  • MODBUS, Bluetooth, BACnet protocol

 

 

Specification

Excitation:

Keypad:
DC Plused 3 external keys for programming
Display: and display control
4 lines LCD with backlight Low Flow Cutoff:
Line 1 0 to 9.9%
Date and Time Data Logger Function:
Line 2 99 date/ time records for alarm
6 digit flowrate Record Data:
6 digit energy value Date/ time of power on/ off
Error code 99 years flow rate/ energy/
Supply temperature temperature/ total flow/ total energy
Line 3 Record data every one hour
9 digit totalizer for forward flow/ reverse flow  Damping:
9 digit totalizer for heat / cold energy 0.1 to 99.9s
Error code content Self Diagnosis:
Return temperature The following error message are
Line 4 displayed if failure occurs
Differential temperature - Coil failure
Unit - Temperature failure
L/S, L/M, L/H, M3/S, M3/m, M3/H, ML/H, ML/m  - Temperature anomaly
ML/S, KW, MW, KJ/H, MJ/H, GJ/H, Mcal/H - Zero point anomaly
Kcal/H, Cal/H - Empty pipe
Measuring Range: - EEPROM anomaly
Min. 0 to 0.15 m/s Cable Entry:
Max. 0 to 15 m/s Standard: M20 Option1/2"NPTF
Accuracy: Protection Class:
+/-0.2% of reading (Velocity >= 0.5 m/s) IP 67
+/-0.001 m/s (Velocity < 0.5 m/s) Ambient Temperature:
Repeatability: -25 to + 65oC
+/-0.05% of reading Material:
Current Output: Aluminum Alloy
4-20 mA(isolated) Temperature Input:
Load PT1000, 2 wire
Max. 600  Power Supply:
Pulse Output: 90-260 VAC, 50/60 Hz
Open collector 24VDC +/-10% (Option)
Rating Power Consumption:
3 to 30 VDC, 50 mA Max. 10~20 W (Dependent on sensor size)
Pulse Rate: Weight:
1) Scale pulse, (Pusle/M3, Pulse/L,Other) 4.5 Kg
2) Frequency: 0-5000 Hz Mounting:
Communication: Bracket on 2" pipe
Bluetooth (Apply to Android System)  
RS485 (MODBUS Protocol) / BACnet  
Data Storage:  
Operation parameters and totalizer  
figures are stored by EEPROM for more  
than 10 years
M&C ENGINEERING
유량계 및 각종 계기 전문업
M & C Engineering, Inc. is a established in 1999. Since the company's inception, we have worked continuously to supply instruments and flow meters of various and notable manufacturers. We are also leading sales representative company which is specialized in flowmeter in Korea and our staffs have been working on this business more than 15 years in Korea. We,therefore, are known in korea market very well. Based on our marketing goal and combined with the manufacturer's high standard of technology, manufacturing, quality, delivery, etc. We will always look out from our customer's perspective so that we may be the most reliable partner who always exceeds the expectations of our customers. We will always look out from our customer's perspective so that we may be the most reliable partner who always exceeds the expectations of our customers.
Inquiry