Industrial boiler manufacturer
Ecomonic:
① Micro smoke tube type structure that best fitness in small space installation.
② Realize high effectivenedd by optimum internal pressure in flue and installation of air pre-heater.
③ Reduce the fuel cost by reserve subordinate time (within 15 minutes)
④ It is horizontal type combusting structure with long-range of life-time durability
· Convenience:
① Automatic controlling system that all functions are achieved perfectly by single-touch
② Great convenience to manage and operate by the built in type additional equipment which related to automation.
③ High safety by the double or triple safety control system
④ Easy to manage and repair by the manual control system
· Place to use:
Fiber / Sewing factory / Chemical factory / Heating and hot-water supply / Sauna / Dye works / Hotel / Hospital / Drying rack / Laboratory / Bean curd factory / Brewery / Food factory / Drying rack / Brickyard / Deposit factory etc.
Division / Type |
SMB-100 |
SMB-150 |
SMB-200 |
SMB-250 |
SMB-300 |
SMB-350 |
SMB-400 |
SMB-500 |
||
Proper Form of Evaporation |
kg/h |
1,000 |
1,500 |
2,000 |
2,500 |
3,000 |
4,000 |
5,000 |
6,000 |
|
Max. Working Pressure |
kg/㎠ |
10{1.0MPa} |
||||||||
Efficiency |
% |
More than 90% |
||||||||
Electric Transmission Area |
㎡ |
13 |
21.6 |
24 |
32.3 |
42 |
49.7 |
55 |
66 |
|
Weight |
Ton |
2.2 |
2.5 |
2.8 |
3.2 |
4.0 |
4.5 |
5.2 |
6.3 |
|
Titration |
ℓ |
1,300 |
1,383 |
1,687 |
1,927 |
2,775 |
3,013 |
5,303 |
6,890 |
|
Fuel Consumption |
Light Oil |
kg/h |
67.5 |
101.3 |
135.1 |
168.9 |
202.6 |
236.4 |
270.2 |
337.7 |
LNG |
N㎥/h |
70.3 |
105.4 |
140.6 |
175.7 |
210.8 |
246 |
281.1 |
351.4 |
|
LPG |
N㎥/h |
31.1 |
46.6 |
62.2 |
77.7 |
93.3 |
108.8 |
124.4 |
155.4 |
|
Heavy Oil |
kg/h |
68.2 |
102.3 |
136.4 |
170.5 |
204.6 |
238.7 |
272.8 |
341.1 |
|
Capacitance of Electric |
kW |
4.8(6.35) |
6.35(8.1) |
8.45(10.45) |
10.45(10.45) |
11.25(14.75) |
16.2 |
16.2(20.2) |
20.2 |
|
|
Main Steam Valve |
A |
50 |
65 |
80 |
80 |
80 |
100 |
100 |
125 |
Progression Valve |
25 |
25 |
40 |
40 |
40 |
40 |
40 |
40 |
||
Drainage Valve |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
40 |
||
Safety Valve |
25 |
32 |
40 |
40 |
40 |
50 |
25,40 |
40×2 |
||
Feed Oil Valve |
20 |
20 |
25 |
25 |
25 |
25 |
25 |
25 |
||
Fuel Gas |
25 |
40 |
40 |
40 |
50 |
50 |
50 |
50 |
||
Chimney |
ømm |
300 |
350 |
400 |
500 |
550 |
580 |
600 |
650 |
|
Minimum Dimension |
Width |
mm |
1,300 |
1,340 |
1,450 |
1,450 |
1,710 |
1,800 |
2,140 |
2,240 |
Length |
2,950 |
3,070 |
3,203 |
3,570 |
3,620 |
3,620 |
4,100 |
4,890 |
||
Height |
2,040 |
2,130 |
2,377 |
2,500 |
2,587 |
2,800 |
2,920 |
3,210 |
||
Maximum Dimension |
Width |
mm |
1,980 |
2,074 |
2,200 |
2,248 |
2,640 |
2,800 |
2,980 |
3,328 |
Length |
3,000 |
3,164 |
3,420 |
3,420 |
3,840 |
3,840 |
4,320 |
5,240 |
||
Height |
2,290 |
2,400 |
2,500 |
2,900 |
3,020 |
3,320 |
3,570 |
3,780 |
※ Low calorific power of fuel
① LNG:41.45 MJ/N㎥{9,900kcal/N㎥}, ② LPG{Propane}:93.7 MJ/N㎥{22,380kcal/N㎥},
③ Light Oil:43.12 MJ/kg{10,300kcal/kg}, ④ Heavy Oil:42.7 MJ/kg{10,200kcal/kg}
※ The specification list are subject to change without prior notice to improve the performance and technology development.