Electric power control device, Electric power controller, Motor starter, Power supply device and more
SMC-UNIT (Motor Soft Starter)
[1] Introduction
Seron's Motor Controller SMC-Unit is designed and assembled to the highest standards so our customers can achieve a maximum machine life and save energy by reducing a starting inrush current which can be reached as much as 7-12 times the full load current of the motor during start-up, and by decreasing the starting torque which is much higher than at full load. And also customers can save a maintenance cost by relaxing mechanical shock by soft start and down too. And it is also designed so that all the functions and parameters are digitally controlled and displayed at the segment of its cover. 2.2-350 KW for AC 220V, 380V, and 440V for three-phase for both single and dual direction types are available. The old model and New model are provided.
Especially New model Motor Soft Starter New SMC-Unit), which is designed and produced to the most advanced technologies in the industry, is a technology-condensed one so as to be able to call a next-generation product as for the Motor Soft Starter. There are various kinds of models such as the plastic case type-C which is applied in low capacity motor, and while the steel case type which is applied in the high capacity motor. And also because the cooling efficiency is maximized by using the epochal improved heat sink, the Unit becomes smaller, lighter, and economical much more than the existing Unit in the world.
[2] Application
- Hoist & Crane | - Fan & Blower | - Conveyor | - Pump | - Blender & Mixer |
- Saw(Cross&Band) | - Milling Machine | - Agitator | - Crusher | - Grinder |
[3] Appicable equipments
- The Motor which need a reduction of the inrush current and soft start
- The Motor which need a soft stop
- The Motor which need a frequent start and stop
- The driving Motor which use the method of move-in by Star-Delta, Reactor and Resistor
- The equipment which need a stable operation and extension of long mechanical life
- The driving Motor which is installed in area containing much dust and gas
[4] Model Identification
[5] Basic Specification
Input Voltage Rating | - AC220V - AC380V - AC440V Frequency : 50 and 60Hz |
Allowable Isolation | DC 1500V for one minute between case & case, and case & earth terminal |
Allowable Input Voltage | ±115% of Input Volt Rating | Alarm Output | One point relay Output |
Control Power | Lower than 5W | Communication | Degree : EIA, RS485 (Option) |
Order Input Method | Digital | Alarm Function | Required Alarm-Selective Function |
Accuracy of Order | 5/1000 FS | Installation | Installation in indoor panel |
ACCuracy of Parameter | 100% | ||
Case Materials |
- New Model : Low capacity : Plastic case, Medium and high capacity : steel case |
||
Note - The auto and communication mode are an option. When you place order, please make sure your specification again |
[6] Out line Drawing & Size table
6-1. Old Model
Size (mm) Currtent (A) |
H | H1 | W | W1 | D |
~40 | 350 | 290 | 200 | 120 | 170 |
~60 | 380 | 320 | 200 | 120 | 220 |
70~250 | 510 | 450 | 270 | 200 | 255 |
~550 | 560 | 500 | 307 | 225 | 285 |
600A or Higher | On customer's specification |
* This specs may be changed by Design Change and Modification
6-2. New Model
Capacity (KW) | H | W | D | W1 | H1 | 비고 | |
220V | 3.7 KW (12A) or Lower | 85 | 120 | 165 | 110 | 45 |
Plastic case-C type |
380V | 7.5 KW (14A) or Lower | ||||||
220V | 5.5KW ~11KW | 320 | 230 | 230 | 90 | 280 | Steel Case 형 |
380V | 11KW ~ 22KW | ||||||
220V | 15KW ~ 22KW | 440 | 185 | 240 | 105 | 400 | |
380V | 30KW ~ 37KW | ||||||
220V | 30KW ~ 110KW | 500 | 250 | 240 | 150 | 450 | |
380V | 45KW ~ 180KW | ||||||
220V | 130KW ~ 180KW | 640 | 400 | 280 | 250 | 620 | |
380V | 200KW ~ 300KW | ||||||
220V | 200KW or Higher | Customer's Specification | |||||
380V | 350KW or Higher |
* Please note that in case dual-direction type the size may be changed