TOP
Portable PT Ratio & Error Tester and CT/PT Ratio & ERROR Tester manufacturer
INTRODUCTION
① Automatic Control Test Equipment, integrated with PLC and HMI (SCANADA) System, can carry out PT Test and CT Test for Turns Ratio of Current Transformer
② Portable Type and Fixed Type of Tester, carry out the test at anytime in anywhere for production or maintenance filed of PT and CT. (Factory and Labaratories too)
③ Touch Screen and low output voltage maxmizes the user's safety and convenience as per the below functions.
* "PORTABLE CURRENT TRANSFORMER OF EXCITING CURRENT AND CORE CHARACTERISTICS TESTER" IS PATENT REGISTERED: 2020. 11. 11.
* RATIO ERROR TESTER (PLC + HMI FUCTION) IS PATENT REGISTERED: 2020. 12. 10.
PT/CT Measurement Function
① It Includes all the functions in PT Ratio Error Tester. Also it can measure Pierce Type and Coil Type (Including Single Phase and 3 Phase)
Exciting Current Test
① Measure Exciting Current Value of CT by adding Simple Type of Exciting Current Tester. Safe and Fast Measurement (2nd Current1A, 5A)
② Guarantee safe Measturement for Max Power Test Voltage (Below AC 50V).
③ Provide all types of PT, CT Wiring Diagram for Test Purpose.
Ratio Measurement Range
① PT: 1~225(110V/110V~24750/110V, 220V/220V~49500V/220V)
② ACCURACY: ±0.5% of Ratio
③ CT: Coil Type 1~ 4000 × T (T = Test lead's Turn number, Max 2 Times)
④ ACCURACY: ±0.5% of Ratio
UM-CPT221 BASIC
MEASUREMENT RANGE | PT, VT SINGLE PHASE (1P2W) - RATIO : 1~210 PIERCE TYPE CT - RATIO : 1 ~ 8,000 COIL TYPE CT - RATIO : 1 ~ 600 |
ACCURACY | ±0.5% of RATIO |
HMI | LCD 7INCH |
CASE | ALUMINUM CASE |
USB | MEMORY FUNCTION |
TEST LEAD WIRE | 4EA |
UM-CPT223 ADVANCED
MEASUREMENT RANGE | PT, VT(1P3W/3P3W/3P4W Y-Y/3P4W △-Y) CT 3PHASE (3P3W/3P4W) SINGLE PHASE GPT (PRI/2nd-3rd) SINGLE PHASE 1P2W (1st-2nd-3rd) SINGLE PHASE TAP : 2-3 TAP Voltage PT,VT - RATIO : 1~210 CT SINGLE PHASE (1P2W) PIERCE TYPE CT - RATIO : 1~8,000 COIL TYPE CT - RATIO : 1~600 |
ACCURACY | ±0.5% of RATIO |
HMI | LCD 10INCH |
CASE | HARD CASE |
USB | MEMORY FUNCTION |
TEST LEAD WIRE | 12EA |
CT RATIO TEST CHARACTERISTICS
① CT RATIO TEST, based on it's own data - carry out automatic selection of secondary Circuit, which exciting Current is not overloaded by calculating the suitable data following by Set Parameter (PRI.A/ SEC.A, BURDEN, CLASS).
② "Pierce CT Type Test" can increase the measurement accuracy of Ratio Range by using Probe (Inside 5 UTRN)
③ It can increase the accuracy of "Non Burden ratio Error" by applying "Correction value of OFF-SET"
* Example:Display 60 Ratio after input 0.387 in Offset Value to adjust Ratioa vlaue in T Column.
SPECIFICATION
UM-PT221 BASIC | UM-PT223 BASIC | UM-PT223-7 ADVANCED | UM-PT223-10 ADVANCED | UM-CPT221 BASIC | UM-CPT223 ADVANCED | |
TOUCH PANEL FEATURES | ||||||
LCD Size | 7 inch | 7 inch | 7 inch | 10 inch | 7 inch | 10 inch |
Resolution | 800 × 480 | 800 × 480 | 800 × 480 | 800 × 600 | 800 × 480 | 800 × 600 |
Luminance | 400cd/㎥ | 400cd/㎥ | 400cd/㎥ | 700cd/㎥ | 400cd/㎥ | 700cd/㎥ |
CASE | Aluminum | Aluminum | Hard | Hard | Aluminum | Hard |
PT Test List | ||||||
1P2W | Y | Y | Y | Y | Y | Y |
GPT | Y | Y | Y | Y | ||
TAP VT | Y | Y | Y | Y | ||
1P3W | Y | Y | Y | Y | ||
3P3W | Y | Y | Y | Y | ||
3P4W(Y-Y) | Y | Y | Y | Y | ||
△-Y | Y | Y | Y | Y | ||
CT Test (WINDOW / DIRECT) | ||||||
1P2W | Y | Y | ||||
3P3W | Y | |||||
3P4W | Y | |||||
CT BURDEN Test | ||||||
Y | Y | |||||
PT RATIO RANGE | ||||||
ALL | 1~125 | 1~210 | 1~210 | 1~210 | 1~210 | 1~210 |
CT RATIO RANGE | ||||||
WINDOW DIRECT | 1~4000 x T * 1~600 |
1~4000 x T * 1~600 | ||||
OTHER FEATHERS | ||||||
Download to USB Memory | Y | Y | Y | Y | Y | Y |
Auto test | Y | Y | Y | Y | Y | Y |
Weight (Kg) | 10 | 10 | 11 | 11 | 10 | 11 |
Size(mm) | W450 X D150 X H350 | W450 X D150 X H350 | W450 X D180 X H350 | W450 X D180 X H350 | W450 X D150 X H350 | |
TEST LEAD SUPLY | ||||||
Basic Lead | 4 | 12 | 12 | 12 | 4 | 12 |
For Window CT Only | Y | Y |
*Maximum Measurement Value is 8,000 Ratio (When Turn Number (T) of WINDOW CT TEST LEAD is controlled)