Manufacturer of Mamometer temperature sensor, Flowmeter, Level gauge, Transmeter
Service intended
P254 series are designed to measure a high dynamic pressure load and it can be used where severe vibrations are present. It is recommended to be used with a gaseous and a liquid media that are not highly viscous and not to be used where copper alloy parts could be corroded. Its application extends to hydraulics, compressors and shipbuilding.
Nominal diameter | 50, 63, 75 and 100 mm |
Accuracy | ±1.5 % of full scale |
Scale range (MPa, kPa, bar) | -0.1 ~ 0 to 0 ~ 40 MPa |
Working pressure | Steady : 75 % of full scale Over range protection : 130 % of full scale |
Working temperature | Ambient : -20 ~ 60 ℃ -20 ~ 60 ℃ (With glycerin filling) -40 ~ 65 ℃ (With silicone filling) Fluid : Max. 60 ℃ |
Fluid | Glycerin |
Degree of protection | EN60529/IEC529/IP67 |
Temperature effect | Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.4 % per 10 ℃ of full scale |
Standard features
Pressure connection | Brass (50 and 63 mm) Nickel plated brass (75 and100 mm) |
Element | Brass <6 MPa : C type bourdon tube ≥6 MPa : Helical type bourdon tube |
Case | Stainless steel (304SS) |
Cover | Stainless steel (304SS) Crimp ring type |
Window | Polycarbonate (50 and 63 mm) Safety glass (75 and100 mm) |
Movement | Brass |
Dial | White aluminium with black graduations |
Pointer | Black painted aluminium alloy |
Process connection | 50 and 63 mm : ⅛", ¼" PT, NPT and PF 75 mm : ¼", ⅜" PT, NPT and PF 100 mm : ¼", ⅜", ½" PT, NPT and PF One piece type connection (50 and 63 mm) Two piece type connection (75 and 100 mm) |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.