Manufacturer of Mamometer temperature sensor, Flowmeter, Level gauge, Transmeter
Service intended
P790 series diaphragm seal are suitable for conditions where the process medium can cause corrosion to the instrument connection and the pressure sensing element, which the process medium contains suspended solid particles are viscous and be clossed. It is also suitable for where the process medium can freeze or solidify the internal parts of the instrument and where the medium requires flushing from the system to prevent contamination.
Design | Instrument welded diaphragm with threaded process connection, require hydraulic fluid to transmitter pressure to instrument. |
Filling liquid | Silicone oil |
Working temperature | Ambient : -20 ~ 65 °C Fluid : Refer to filling liquid reference table |
Diaphragm material | Diaphragms are available in many corrosion resistant materials. Compatibility of selected material and process fluid should be determined by the user |
Temperature effect | Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale |
Standard features
Upper flange (Gauge side) | Stainless steel (304, 316), Titanium, Monel |
Diaphragm material | Stainless steel(316L) Hastelloy C-276, Titanium, Tantalum, Monel |
Pressure connection | Thread type : PT, PF, and NPT others feasible Flange type : ANSI(ASME), JIS or other standard |
Capillary | Capillary : Ø3.0 mm, 316L Flexible tube : Ø7.5 mm, 304, PVC coated |
Note | PTFE lining is available up to 7 MPa (Coating) |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.