Manufacturer of Mamometer temperature sensor, Flowmeter, Level gauge, Transmeter
Service intended
P740 series have diaphragm seal to be combined with a pressure gauge, and measure the melted plastics, fiber, and synthetic under high pressure. It is suitable to be used for the situation where corrosive, contaminated, hot and viscous pressure mediums are present during the chemical or food process.
Pressure range (MPa, bar) | Refer to range table Depending on diaphragm size and process conditions |
Accuracy | ±1.0 % of full scale |
Filling liquid | Silicone oil |
Working temperature | Ambient : -20 ~ 65 ℃ Fluid : Max. 300 ℃ |
Temperature effect | Accuracy at temperature above and below the reference temperature (20 ℃) will be effected by approximately ±0.5 % per 10 ℃ of full scale |
Standard features
Process connection | ¾" PF and 1" PF male screw |
Body | Stainless steel (316SS) |
Diaphragm | Stainless steel (316L SS) |
80, 150 and 300 mm | |
Certificates | ATEX Ex II GD c IIC TX |
© WISE Control Inc. All rights reserved. ALL PRODUCT, PRODUCT SPECIFICATIONS AND DATA ARE SUBJECT TO CHANGE WITHOUT NOTICE TO IMPROVE RELIABILITY, FUNCTION OR DESIGN OR OTHERWISE.