Service intended
Protection tube type is constructed with the insulator which insulates the element wire, and with the protection tube which protects the insulator. To install this model on the process pipe or on the container, it normally attaches to a connector, a flange, or a compression fitting on the protection tube. It can be manufactured as it is required for its use. As its special features, it does not have any resistance issues with a lead wire, and its immediate response to a temperature change leads to a less error rate of temperature change in a broade range.
Standard features
Element | Thermocouple : K, E, J, T, N RTD : Pt 100 Ω at 0 ℃ |
Head material | ALDC (Standard) 316SS |
Certificates | KCS Ex d e IIC T6 IP67 |
Tolerance on temperature reading | ■ Thermocouple Class 1, Class 2 (DIN/IEC584-2, BS/EN60584-2, JIS C1602) Special, Standard (ASTM E230, E988, ISA-MC96.1) ■ RTD Class A : ±(0.15 + 0.002 l t l) Class B : ±(0.3 + 0.005 l t l) |
Protecting tube outer diameter (RTD only) | 6.4, 8.0 and 10 mm |