COFAS is abbreviation of Corrugated Factory Automation System.
• COFAS (Corrugated Factory Automation System)
- Communications between respective control system and data server will be handled by Ethernet.
- In case of long distance between servers, it can have a good result from processing with optical communications
• Main Host Server (work scheduling server and company office management server)
- This is Data server to manage work order data or work schedule of Flexo Machine
- This is not managed by WSA ( but by Customer’s server)
• COFAS Server (Conveyor Automatic Control Server)
- Data management of each Conveyor and Sheet information management, It takes Data handling with Main Host Server
- O.S : Windows 2012 Server
- Data Base : MS SQL
- Use “Mirroring” to utilize Two Static Memory Hard disk to prevent data lost from hard disk fail
- Development TOOLS : Delphi , java combined.
• COFAS Server Program
- PLC #1, PLC#2 … It can be communicated with COFAS Server through Ethernet
- Conveyor control modules is followed by control program order of the server and managed in real time
- Operator of Flexo Machine automatically find and supply sheets within conveyor buffer section if operator choose
progress or work list on standby
- It needs work list data of Flexo Machine and Work instruction data from Main Host Server
- It needs exit sheet information at the exit position from stacker.
- It can be controlled and understanding sheet flow in real time at the Office or Control Room
- COFAS System Flow
- COFAS Real Time View Screen