Automatic valve, Electric ball valve, Control valve, Globe valve, Actuator and more
Standard Materials of Construction
NAME | NO. | SPECIFICATION |
Outer Position Indicator | 1 | PE |
Inner Position Indicator | 1 | ABS |
Housing | 2 | Die-Casting Aluminum |
Shaft (stem) | 1 | 303 Stainless Steel |
Mechnical Switch | 2 | Used in UL CSA approved |
Inserts | 2 | Bronze |
O-Ring | 4 | Nitrile (Rubber) |
Cam | 2 | ABS |
Spring | 1 | 304 Stainless Steel |
Cover Screws | 4 | 304 Stainless Steel |
Terminal Strip | 1 | Polyethylene |
Specification
Description | Series | |
Model | ALS 1X Series | ALS 3X Series |
Ambient Temperature | -20℃ to 85℃ (-4˚F to 185˚F) | |
Cable Entry Standard | 2 x 1/2" PF/PT | 2 x 3/4" PF/PT |
Cable Entry Option | 2 x 1/2" NPT/M20/PG13.5 | 2 x 3/4" NPT/M20/M25/PG13.5/PG16 |
Terminal Block Standard | 8 Points | |
Terminal Block Option | 12 & 14 Points / Solenoid Valve Connection 14 Points | |
Position Indicator | 0˚ to 90˚ (Red for Close / Yellow for Open) | |
Painting | Polyester Powder Coating with Black Color | |
Bracket | Aluminium / Steel / SUS |
Certificate
Mark | ALS 1X Series | ALS 3X Series | |||
Ratings | Reg No. | Ratings | Reg No. | ||
KCS | IP68 | 2011-455-739 | EX d IIC T6 IP67 | 10-AV2BO-0247 | |
CE (TUV NORD) | Low-Voltage Directive 2006/95/EC | K3441/L10 | Low-Voltage Directive 2006/95/EC | K3441/L10 | |
FM Approvals |
XP/I/1/ABCD/T5Ta=+85˚ C:I/1/AEx d IIC/T5 Ta=+85˚ C; DIP/II, III/1/EFG/T5 Ta=+85˚ C;IP67 |
3041064 |
Dimension
Mounting Bracket
1 NAMUR standard bracket is supplied together with 1 limit switch box as standard
Model | Bracket | Material | Size | Model | Bracket | Material | Size |
S1 ALS 1X Series |
Steel | 30 x 80 H:20~30 |
A1 ALS 3X Series |
Aluminum | 30 x 80 H:20 |
||
AB1 ALS 1X Series |
SUS | 30 x 80 H:20 |
A2 ALS 3X Series |
Aluminum | 30 x 80 H:30 |
||
AB1 ALS 3X Series |
SUS | 30 x 80 H:20 |
A3 ALS 3X Series |
Aluminum | 30 x 130 H:30 |
Wiring Diagram