Air gab brake motor and fan manufacturer, Ring blower, Small high speed blower, Turbo blower and more
HRB-501 Single Phase [1Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
| HRB-501 | ||
50Hz | 60Hz | ||
PHASE | 1 | ||
MOTOR | HP | 2.5 | 3.0 |
Kw | 1.83 | 2.2 | |
PRESSURE | mmAq | 2100 | 2100 |
VACUUM | mmAq | 2000 | 2000 |
MAX . AIR FLOW | ㎥/min | 5.0 | 6.0 |
CURRENT|220V | A | 16.0 | 22.0 |
SOUND LEVEL | dB(A) | 76 | |
MATERIAL | IMPELLER | Aluminum | |
CASING | Aluminum | ||
BEARING | FRONT | 6206ZC3 | |
MIDDLE | - | ||
REAR | 6205ZZC3 | ||
WEIGHT | Kg | 39 | |
INSULATION CLASS | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%