Air gab brake motor and fan manufacturer, Ring blower, Small high speed blower, Turbo blower and more
HRB-1102, HRB-1102MP, HRB-1202, HRB-1202MP Three Phase [3Ø]
- The allowable Tolerance of dimension is ± 5mm.
- The dimension can be changed for improvement without notice
Performance & Specifications
The blower with the name suffix MH (Motor High-efficiency) is designed to run at 60Hz.
| HRB-1102MP | HRB-1102 | HRB-1202MP | HRB-1202 | ||||||
50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | 50Hz | 60Hz | |||
PHASE | 3 | 3 | 3 | 3 | ||||||
MOTOR | HP | - | 16.8 | 15.0 | 16.8 | - | 23.0 | 20.0 | 23.0 | |
Kw | - | 12.6 | 11.0 | 12.6 | - | 17.3 | 15.0 | 17.3 | ||
PRESSURE | mmAq | - | 6200 | 5500 | 6200 | - | 7200 | 6500 | 7200 | |
VACUUM | mmAq | - | 4300 | 4000 | 4300 | - | 4800 | 4500 | 4800 | |
MAX . AIR FLOW | ㎥/min | - | 9.5 | 8.0 | 9.5 | - | 9.5 | 8.0 | 9.5 | |
CURRENT | 220V | A | - | 45.0 | 40.0 | 50.2 | - | 50.2 | 40.7 | 56.0 |
380V | A | - | 26.0 | 23.1 | 29.0 | - | 29.0 | 23.5 | 32.3 | |
SOUND LEVEL | dB(A) | 82 | 82 | 82 | 82 | |||||
MATERIAL | IMPELLER | Aluminum | Aluminum | Aluminum | Aluminum | |||||
CASING | Cast Iron | Cast Iron | Cast Iron | Cast Iron | ||||||
BEARING | FRONT | 6207ZC3 | 6207ZC3 | 6207ZC3 | 6207ZC3 | |||||
MIDDLE | - | - | - | - | ||||||
REAR | 6308ZC3 | 6308ZC3 | 6308ZC3 | 6308ZC3 | ||||||
WEIGHT | Kg | 240 | 240 | 250 | 250 | |||||
STARTING CLASS | K | K | K | K | ||||||
INSULATION CLASS | F | F | F | F |
- The performances above were measured under conditions of air temperature 20 °C and atmospheric pressure 1,013mbar.
- The allowable tolerance of the performance value is +10%
- The sound level was measured at a distance of 1.5m with the fully open inlet and outlet ports.
- Anti-corrosive and explosion-proof treatments can be applied upon request.
Performance Curve
- The continuous operation can be made at a point below the curve, however, the continuous operation nearby the rated pressure point may cause a motor breakdown.
In the case of the continuous operation close to the rated pressure, it is strongly recommended to use the pressure-relief valve. See accessories, page 61.
- The allowable tolerance of the performance value is ± 10%