product Image

TOP

Air Source Heat Pump
Model Name
IAT-16A-01/05 Series
Data
-
Manufacturer information
provider logo
IL-JIN E-PLUS

Energy saving device manufacturer, Waste water heat heat pump, Air heat heat pump, Geothermal heat pump and more

Problem with product info?
Update request
Manufacturer
IL-JIN E-PLUS
Brand
-
SKU
60725
Product Name
Air Source Heat Pump
Model Name
IAT-16A-01/05 Series
Size
-
Weight
-
Product Details

IL-JIN E-PLUS Air Source Heat Pump IAT-16A-01/05 Series

* Product Overview

A system that utilizes the external air for the heat pump to provide heating and hot water

 

* Features

① All-in-one Air Source Heat Pump Water Heater
② EVI small-volume Air Source Heat Pump - Air Source Heat Pump for cold areas which can produce high-efficiency energy in the cold season (-15℃) through combining new refrigerant R-410A and EVI compressor

 

* Application

Hotels, motels, dormitories, hospitals and restaurants, among others (all places needing hot water and heating)

 

* Air Source Heat Pump Water Heater (IAT-16A-01)
   EVI Air Source Heat Pump (IAH-16A-01)

Model

IAT-16A-01

IAH-16A-05

Capacity

Heating

KW

2.8

17

Kcal/h

2,408

14,620

USRT

0.79

4.83

Power Consumption

KW

0.88

6.8

Power Supply

1P * 220V * 60Hz

3P * 380V * 60Hz

Dimension

Length

mm

568

1,108

Height

1,670

1,075

Depth

568

568

Compressor

Type

Scroll type

EVI Scroll type

Quantity

1

1

Driving Method

Direct-on-line

Volume Control

%

0~100%

Refrigerant

Type

R-410A

Control Method

Thermostatic expansion valve

Condenser

Type

Brazed Plate type

Circulation Volume

LPM

1.1

5.1

Piping(IN/OUT)

A

20

25

Outdoor unit

Type

Finned Copper Tube Type

Thermal Storage Area

m2

0.36

1.09

Fan & Motor

Air
Volume

m3/min

8.3

83

Size

Ø

153

460

Tank Capacity

L

190L built-in type(STS)

Separate installation

Control

Temperature Control

Auto inlet/outlet temp control

Operation Control

PCB

Defrosting

Hot Gas

Weight

kg

67

200

Conditions for the products

heating

Outdoor (DB20°C, WB15°C); Temp of water supply to be 15°C; Temp of output water to be 55°C

Outdoor (DB7°C, WB6°C); Temp of water supply to be 7°C; Temp of output water to be 55°C; T=48°C

■ The above specification may vary depending on the site and temperature conditions.
■ The above specification may change without prior notice for further improvement.

IL-JIN E-PLUS
Energy saving device manufacturer, Waste water heat heat pump, Air heat heat pump, Geothermal heat pump and more
Inquiry