Circuit breaker, Switch, Electric contact, Heavy electric machine parts, Automatic transfer breaker, Air circuit breaker and more
① Reliable transfer by excellent "latching" action
② Maximum electric conduction with the minimum operation current
③ Outstanding opening and closing performance
④ Small size and light weight
⑤ Suitable for the emergency power supply Facilities
⑥ Capable of handing both AC and DC
■ Specification
Rated voltage(V) | AC 660V and DC 125V | ||||||||||||||||||||||||||||||||||||||||||||
Rated current(A) | 100A | 200A | 400A | ||||||||||||||||||||||||||||||||||||||||||
Connection | Front or Back | ||||||||||||||||||||||||||||||||||||||||||||
Number of poles(P) | 3P | 4P | 3P | 4P | 3P | 4P | |||||||||||||||||||||||||||||||||||||||
Opening time | 60 ms | ||||||||||||||||||||||||||||||||||||||||||||
Change-over time | 80 ms | ||||||||||||||||||||||||||||||||||||||||||||
Operation corrent | AC 100 / 110V (RMS) | 12A | 12A | 12A | 12A | 16A | 16A | ||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AC 200 / 220V (RMS) | 6A | 6A | 6A | 6A | 8A | 8A | |||||||||||||||||||||||||||||||||||||||
DC 110V | 12A | 12A | 12A | 12A | 16A | 16A | |||||||||||||||||||||||||||||||||||||||
Rated short-tiom current (1 sec) | 5 KA | 10 KA | 12 KA | ||||||||||||||||||||||||||||||||||||||||||
Short circuit peak value | 12.5 KA | 25 KA | 30 KA | ||||||||||||||||||||||||||||||||||||||||||
Weight (㎏) | Fornt type | 13 | 14 | 13 | 15 | 18 | 21 | ||||||||||||||||||||||||||||||||||||||
Back type | 13 | 14 | 13 | 15 | 18 | 21 | |||||||||||||||||||||||||||||||||||||||
Performance | Mechanical life span | 10,000 Times | |||||||||||||||||||||||||||||||||||||||||||
Electrical life span | 3,000 Times | ||||||||||||||||||||||||||||||||||||||||||||
Switching frequency | 150 Times / Hour |
■ Operating Circult Diagram(AC)
■ Operating Circult Diagram(DC)
Symbol | Function | Symbol | Function |
---|---|---|---|
A Power | Normal power source | B Power | Emergency power source |
C1 | Normal side closing coil | C2 | Emer. side closing coil |
S1, S2 | Silicon rectiifier | Xa, Xb | Control Contact |
a1~a4 | A Power Aux Switch | b1~b4 | B Power Aux Switch |
■ Distinctive
1. Mold type, compact design
This product broke away from the traditional assembly method and reduced the appearance dramatically by designing each phase into a stand-alone mold.
2. Intermediate shutdown
The design allows a neutral position (OFF) using a trip device and switches after stable load and safety are secured.
A=>off=>B , B=>off=>A , A=>off=>A , B=>off=>B A=>B, B=>A switching is also possible by using the operating instruction.
3. Detachable arc extinguishing chamber
This innovative design enables it to check any wearing or damage of the contact point even during operation. The extinguishing capability is increased through an independent detachable arc extinguishing chamber.
■ Specification
Rated voltage(V) | AC 660V, OR DC 125V | |||||||||||||||||||||||||||||||||||||||||||||||
Rated current(A) | 600 | 800 | 1000 | 1200 | 1600 | 2000 | 2500 | 3200 | ||||||||||||||||||||||||||||||||||||||||
Number of poles (P) | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | 3 | 4 | ||||||||||||||||||||||||||||||||
Weight(Kg) | 26 | 33 | 31 | 39 | 32 | 40 | 34 | 42 | 40 | 48 | 46 | 56 | 47 | 57 | 54 | 66 | ||||||||||||||||||||||||||||||||
Operating current | DC 110V | 14 | 16 | 16 | 20 | 16 | 20 | 16 | 20 | 20 | 24 | 24 | 30 | 30 | 36 | 36 | 44 | |||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
AC 100/110V(RMS) | 14 | 16 | 16 | 20 | 16 | 20 | 16 | 20 | 20 | 24 | 24 | 30 | 30 | 36 | 36 | 44 | ||||||||||||||||||||||||||||||||
AC 200/220V(RMS) | 7 | 8 | 8 | 10 | 8 | 10 | 8 | 10 | 10 | 12 | 12 | 15 | 15 | 18 | 18 | 22 | ||||||||||||||||||||||||||||||||
Trip coil current | AC/DC 110V = 1A, AC 220V = 0.5A | |||||||||||||||||||||||||||||||||||||||||||||||
Performance | Rated short-time current(1 sec) | 15 KA | 15KA | 22KA | 22KA | 25KA | 35KA | 35KA | 55KA | |||||||||||||||||||||||||||||||||||||||
Short circuit peak value | 35KA | 37.5KA | 50KA | 50KA | 55KA | 60KA | 75KA | 85KA | ||||||||||||||||||||||||||||||||||||||||
Switching capacity | AC3 (10 le Making, 8 le Breaking cosθ=0.35) | AC2 (4 le Making, 4 le Breaking cosθ=0.65) | ||||||||||||||||||||||||||||||||||||||||||||||
Operating Time | “A”Power | Making | 120 mS | 120 mS | ||||||||||||||||||||||||||||||||||||||||||||
Breaking | 25 mS | 40 mS | ||||||||||||||||||||||||||||||||||||||||||||||
“B”Power | Making | 100 mS | 120 mS | |||||||||||||||||||||||||||||||||||||||||||||
Breaking | 30 mS | 65 mS | ||||||||||||||||||||||||||||||||||||||||||||||
Life | Mechanical | 10,000 Times | 10,000 Times | |||||||||||||||||||||||||||||||||||||||||||||
Electrical | 5,000 Times | 5,000 Times | ||||||||||||||||||||||||||||||||||||||||||||||
Switching frequency | 30 Times / Hour | 30 Times / Hour |