Digital power control manufacturer
- Read and write function through EtherCAT communication.
- Improving power factor Distributing momentary maximum output power by sequential control through synchronization, when multiple power regulators are operated at the same time.
- Possible to read and write through PSD(PARA SMART DISPLAY) or communication function. And with just one PSD, every parameter and alarm can be selected for multiple FLEX.
- To detect partial load failure in multiple parallel loads.
- To realize detecting partial load failure immediately and precisely through PARA-ENT its own unique auto-tuning function.
Feature
SMART MPD (Max Power Distribution) Function
- Improving power factor Distributing momentary maximum output power by sequential control through synchronization, when multiple power regulators are operated at the same time.
SMART Communication
- EtherCAT READ&WRITE
- RS-485 2 Wire half-duplex
- MODBUS(RTU),Baud rate MAX: 115,200bps
SMART PLF (Partial Load Failure)
- To detect partial load failure in multiple parallel loads.
- To realize detecting partial load failure immediately and precisely through PARA-ENT its own unique auto-tuning function.
Alarm history
- Last 6 alarms are saved to check out type of alarm easily.
- Even main power is cut off by alarm function, alarm history is saved for better maintenance and user’s convenience.
Convenient parameter setting by PSD
- All parameters and alarms are selected by PSD or RS-485 communication.
- Through selecting parameters and alarms, the usage can be optimized at different circumstances.
- Multiple FLEX products under the same condition and same rated current, all parameters and alarms can be selected with only one PSD using COPY&PASTE function. This is to save time and money. And if you connect PSD to any of FLEX product, you can check out the status of product immediately.
SMART SELF-DIAGNOSIS
- Self diagnosis to check parameter setting, alarm setting and all the wiring status for user’s convenience.
SMART TEST
- When actual load is hardly tested, user can test with small load allowing output arbitrarily.
Ordering Code
① TYPE | FLEX |
② Rated Voltage | 1 : 110VAC 2 : 220VAC 3 : 330VAC 4 : 440VAC 5 : 550VAC |
③ Rated Current | 025 : 25A 040 : 40A 055 : 55A 070 : 70A 090 : 90A 110 : 110A 130 : 130A 160 : 160A 200 : 200A |
④ WIRING | 1P3L : Three shingle phase 3P3L : One three phase |
⑤ PSD(Option) | PSD : With PSD NONE : Without PSD |
⑥ RS-485(Option) | RS : With RS-485 NONE : Without RS-485 |
⑦ EtherCAT(Option) | E : With EtherCAT NONE : Without EtherCAT |
⑧ MPD Option | MPD : With MPD NONE : Without MPD |
Specification
Model | FLEX Power Regulator |
---|---|
Rated Voltage | 110V / 220V / 380V / 440V |
Allowable Voltage Difference | ±10% of Rated Voltage |
Rated Current | 25A ~ 200A |
Frequency | 50/60Hz Auto detect |
Minimum Load | 1A |
Output Range | 0 ~ 94% |
PCB Power | DC 24V |
Power consumption | Max. 13W (Fan included) |
Input signal | 4~20mA(Default) 3CH / 0~5V, 1~5V, 0~10V(Option) |
Alarm | N.O. (2ch, Ic ≤ 1A) |
Digital input | 1ch |
Control method | Phase-Angle(current F/B) / Zero-Crossing(MPD Function: Option) |
Withstand Voltage | 2.3KVAC (Step 1Min) |
Insulation resistance | 220MΩ |
Cooling | Cooling fan basically installed |
Alarm | Over Current, Over Temperature of heatsink(60℃, 80℃), Fuse failure, Load Failure, SCR failure Main power failure(No alarming, LED display), FAN alarm, Partial load failure. Unbalanced load |
Ambient Temp | 0~40℃ |
Humidity | 40~85%RH (No condensation) |
Communication | EtherCAT Slave (Option), RS-485 (Option) |
Display | 3 Color LED (1EA Pilot, 1EA/Each Channel) |
Net WT. | 25A~70: 4.2Kg / 90~200A: 9.0Kg |