모터용량 Motor capacity (KW) | 층고 (Traveling height) 스텝폭 (Step width 1000) | KW | 층고 (Traveling height) 스텝폭 (Step width 1000) | KW | 층고 (Traveling height) 스텝폭 (Step width 1000) | KW |
1000-3300 | 5.5 | 1000-3500 | 5.5 | 1000-3700 | 5.5 | |
3400-4500 | 7.5 | 3600-4700 | 7.5 | 3800-4900 | 7.5 | |
4600-4900 | 8 | 4800-5100 | 8 | 5000-5200 | 8 | |
5000-5900 | 11 | 5200-5900 | 11 | 5300-5900 | 11 | |
스텝폭 (Step width) | A | B | C | D | E | F |
---|---|---|---|---|---|---|
1000 | 1000 | 1158 | 1238 | 1600 | 1660 | 2310 |
800 | 800 | 958 | 1038 | 1400 | 1460 | 2110 |
600 | 600 | 758 | 838 | 1200 | 1260 | 1910 |
모델 (Model) | 층고 (Traveling height) | Net weight KN | Bearing capacity | 기기치수 (Transporation dimension) | ||
R1 KN | R2 KN | h | l | |||
FML(600)-30 (3600Person/h) Speed : 0.5m/s | 3000 | 57 | 46 | 41 | 2750 | 10900 |
3500 | 60 | 49 | 44 | 2780 | 11890 | |
4000 | 64 | 52 | 47 | 2810 | 12880 | |
4500 | 68 | 56 | 50 | 2830 | 13870 | |
5000 | 71 | 59 | 53 | 2840 | 14860 | |
5500 | 75 | 62 | 56 | 2860 | 15860 | |
6000 | 79 | 65 | 59 | 2870 | 16860 | |
FML(800)-30 (4800Person/h) Speed : 0.5m/s | 3000 | 59 | 52 | 47 | 2750 | 10900 |
3500 | 63 | 56 | 50 | 2780 | 11890 | |
4000 | 67 | 60 | 54 | 2810 | 12880 | |
4500 | 71 | 64 | 57 | 2830 | 13870 | |
5000 | 74 | 68 | 60 | 2840 | 14860 | |
5500 | 82 | 74 | 66 | 2860 | 15860 | |
6000 | 86 | 78 | 69 | 2870 | 16860 | |
FML(1000)-30 (6000Person/h) Speed : 0.5m/s | 3000 | 63 | 59 | 53 | 2750 | 10900 |
3500 | 67 | 64 | 57 | 2780 | 11890 | |
4000 | 71 | 68 | 61 | 2810 | 12880 | |
4500 | 75 | 73 | 65 | 2830 | 13870 | |
5000 | 83 | 79 | 71 | 2840 | 14860 | |
5500 | 87 | 84 | 75 | 2860 | 15860 | |
6000 | 92 | 88 | 79 | 2870 | 16860 |
- When the escalator to be installed adove the second floor. Don’t have a pit. Layout drawing must be matched between up and down.
- Keep the sufficient space at both EXIT and EXTRANCE of escalator. The width must be less than 1238. The depth from handrail belt revered end to the front obstacle must be not less than 2500.
- Space between handrail belt of escalator and obstacle must be not less than 500.
- Motor AC 380 V 50 HZ. See in the table
- By the user to provide a grounding resistance of less than 4 ohms.
- Provide by user to the main switch of the power requirements of 3 phases 5 wires.
- All the dimensions are measured by MM.