Small precision motor manufacturer, Induction motor, Speed control, Geared motor
ㆍSpeed Control
ㆍTacho-Generator Type
■ PERFORMANCE DATA (DUTY : CONTINUOUS)
Motor Type | Output (W) |
Voltage (V) |
Freq. (Hz) |
Speed Range (rpm) |
Rated Torque | Rated Current (A) |
Starting | Condenser | ||
---|---|---|---|---|---|---|---|---|---|---|
1200rpm (kgf·cm) |
90rpm (kgf·cm) |
Torque (kgf·cm) |
(V) | (㎌) | ||||||
IHT9PG120-10 | 120 | 1ø100 | 50 | 90~1400 | 8.28 | 2.07 | 1.80 | 4.20 | 250 | 25.0 |
IHT9PG120-11 | 60 | 90~1700 | 8.28 | 2.07 | 1.80 | 5.40 | ||||
IHT9PG120-20 | 1ø110 | 60 | 90~1700 | 9.74 | 2.43 | 1.80 | 6.50 | 250 | 25.0 | |
IHT9PG90-22 | 120 | 1ø200 | 50 | 90~1400 | 8.28 | 2.07 | 1.20 | 4.50 | 450 | 6.0 |
IHT9PG120-22 | 60 | 90~1700 | 8.28 | 2.07 | 1.20 | 5.50 | ||||
IHT9PG90-22 | 1ø220 | 60 | 90~1700 | 9.74 | 2.43 | 1.20 | 6.80 | 450 | 6.0 | |
IHT9PG120-22 | 110 | 1ø220 | 50 | 90~1700 | 8.93 | 2.23 | 1.02 | 6.50 | 450 | 6.0 |
120 | 1ø240 | 50 | 90~1400 | 9.74 | 2.43 | 1.02 | 7.50 |
■ PERFORMANCE DATA (DUTY : 30 Min.)
Motor Type | Output (W) |
Voltage (V) |
Freq. (Hz) |
Speed Range (rpm) |
Rated Torque | Rated Current (A) |
Starting | Condenser | ||
---|---|---|---|---|---|---|---|---|---|---|
1200rpm (kgf·cm) |
90rpm (kgf·cm) |
Torque (kgf·cm) |
(V) | (㎌) | ||||||
RHT9PG120-10 | 120 | 1ø100 | 50 | 90~1400 | 8.28 | 2.07 | 2.30 | 6.00 | 250 | 30.0 |
60 | 90~1700 | 8.28 | 2.07 | 2.30 | 5.50 | |||||
RHT9PG120-11 | 1ø110 | 60 | 90~1700 | 9.74 | 2.43 | 2.30 | 7.50 | 250 | 30.0 | |
RHT9PG120-20 | 120 | 1ø200 | 50 | 90~1400 | 8.28 | 2.07 | 1.30 | 5.50 | 450 | 7.0 |
60 | 90~1700 | 8.28 | 2.07 | 1.30 | 5.50 | |||||
RHT9PG120-22 | 1ø220 | 60 | 90~1700 | 9.74 | 2.43 | 1.30 | 7.00 | 450 | 7.0 | |
RHT9PG120-2C | 110 | 1ø220 | 50 | 90~1400 | 8.93 | 2.23 | 1.14 | 7.50 | 450 | 7.0 |
120 | 1ø240 | 50 | 90~1700 | 9.74 | 2.43 | 1.14 | 8.50 |
- For motor with straight shaft, please write S in place of PG in Motor Type.
- Motor Type in green screen represents the motors with TP(Thermal Protect) according to UL or CE regulation.
- It cannot be used continuously because the temperature rises rapidly when the load is greater than the rated load or the surrounding temperature exceeds 40℃
- when changing the direction of rotation, make sure to turn off the power and reconnect it at stopped state.
■ MOTOR(STRAIGHT SHAFT) I(R)HT9S120 WT 3.7kg
■ GEARED MOTOR I(R)HT9PG120 + 9H□ GB WT 3.7+1.5kg
■ BOLT SIZE
TYPE | BOLT SIZE |
---|---|
9H□ GB | M6×90 |
■ KEY SPEC
■ GEARED HEAD 9H□ GBFWT 1.5kg
■ BOLT SIZE
TYPE | BOLT SIZE |
---|---|
9H□ GBF | M6×25 |
■ KEY SPEC
■ DECIMAL GEAR HEAD 9H10XG WT 0.6kg
■ WIRING DIAGRAM
- The direction of rotation is seen from the end of motor shaft.
- Change the rotation direction of the motor only after the motor stops completely.