1. Description
Constant Wattage Heating Cable is ideally suited for applications where a particular watt density is required at all times. As their name suggests, constant wattage heating cables are designed to deliver the same power output irrespective of pipe temperature. Constant Wattage Heating Cable has a parallel circuit construction and provides uniform wattage regardless of temperature. We normally supply Heating Calbes with a braid and outer jacket but cables can also be supplied with just a braid. This conctant wattage heating cable is flexible at most ambient temperatures and can be wrapped around piping and complex fittings.
Constant Wattage heating cable can be used for a wide variety of applications including freeze protection of pipework and vessels and process temperature maintenance. Also we supply two types of constant wattage heating cable ; the general for low wattage and the industrial for high wattage.
Constant Wattage heating cable is highly flexible and withstand at Max. 250°c. Although not suited for overlapping, its constant output makes it an ideal choice for higher temperature applications where higher watt densities are required.
2. Specificaton
Usage Length 100cm |
Usage Temperature -60°c ~ 200°c |
Voltage 110V / 220V |
Wattage 30 W/m, 40 W/m, 50 W/m |
Bus wire 1.25 SQ |
Packing Unit 100 m /roll |
3. Cable Construction
Model |
No. |
Construction |
Material |
Bare type |
1 |
Bus Wire |
Tinned Copper |
2 |
1st Insulation |
Silicone Rubber |
|
3 |
Heating Material |
Cross winding of Nichrome |
|
4 |
2nd Insulation |
Silicone Rubber |
|
CR / CX type |
5 |
Earth / Reinforcement |
Tinned Copper |
6 |
Outer Insulation |
Silicone Rubber or Fluoro Resin |
4. Cable Model
1) Standard
|
Wattage per meter |
||||
10w |
20w |
30w |
40w |
50w |
|
Bare |
YKH10 |
YKH20 |
YKH30 |
YKH40 |
YKH50 |
CR |
YKH10-CR |
YKH20-CR |
YKH30-CR |
YKH40-CR |
YKH50-CR |
CRS |
YKH10-CRS |
YKH20-CRS |
YKH40-CRS |
YKH40-CRS |
YKH50-CRS |
2) Explosion-proof
|
Wattage per meter |
||||
10w |
20w |
30w |
40w |
50w |
|
Bare |
KHX10 |
KHX20 |
KHX30 |
KHX40 |
KHX50 |
CR |
KHX10-CR |
KHX20-CR |
KHX30-CR |
KHX40-CR |
KHX50-CR |
CRS |
KHX10-CRS |
KHX20-CRS |
KHX40-CRS |
KHX40-CRS |
KHX50-CRS |
5. Cable installation
(Straight run)
With a single straight run, position cable at the bottom of a horizontal pipe. All parts of heating cable must make intimate contact
with surface to be heated. Use heat conductive putty to fill voids between cable and pipe surface. Wrap adhesive tape every
12” (305mm) around heating cable and pipe to attach the cable.
Minimum insulation resistance acceptable after the system has been installed and thermally insulated: The measurement made by applying 500Vdc between each circuit and ground with the set de-energized and all circuit neutrals isolated from ground.
(Spiral wrapping)
Verify the pitch length (see illustration) prior to installation to ensure you have enough heating cable to finish the job. If you need assistance in determining the pitch length, call your local distributor or All parts of heating cable must make intimate contact with surface to be heated. Use heat conductive putty to fill voids between cable and pipe surface.
Wrap adhesive tape every 12” (305mm) around heating cable and pipe to attach the cable. Minimum insulation resistance acceptable after the system has been installed and thermally insulated: The measurement made by applying 500Vdc between each circuit and ground with the set de-energized and all circuit neutrals isolated from ground.