ㆍAdopting 180V~240V single phase type
ㆍInstalled with speed dial that user can select
ㆍMaximizing the work efficiency through high speed
ㆍTriple circuit protection device (Relay & mechanical & P/B)
ㆍDual hoisting limit (electric & mechanical)
ㆍDual break (mechanical & dynamic)
ㆍDual emergency stop function (main power & operation power interception)
ㆍOverload prevention system through mechanical torque limit
ㆍLow power consumption and minimum maintenance cost (1.5~1.8A)
Specification
Model No. | Unit | KEH1S-B180 | KEH1S-B350 | |||||
RATED LOAD | (Kg) | 180 | 350 | |||||
MOTOR POWER | (W) | 300 | 300 | |||||
Standard Lift | (m) | 3 | 3 | |||||
Push button code | L(m) | 2.5 | 2.5 | |||||
Load Chain | (mm) | 4 (1 fall) | 4 (2 falls) | |||||
Weight | (Kg) | 13 | 15 | |||||
Head Room | A(mm) | 400 | 490 | |||||
Height | B(mm) | 300 | 300 | |||||
Speed | m/min at 60 Hz,240V | No Load | 90Kg | 180Kg | No Load | 175Kg | 350Kg | |
UP | Low | CHANGEABLE | 3~6 | 3~6 | 2~5 | 1.5~3 | 1.5~3.0 | 1~2.5 |
High | 10 | 9 | 8 | 5.0 | 4.5 | 4.0 | ||
DOWN | Low | CHANGEABLE | 3~6 | 3~6 | 2~5 | 1.5~3 | 1.5~3 | 1.0~1.5 |
High | 10 | 9 | 6 | 5.0 | 4.5 | 4.5 |
Note
1. The aforesaid specification is subject to change without notice.
2. The aforesaid speed is based on 240V 60Hz and changes depending on input power.
3. Load limiter can be modified before the release at the request of customer.