Smart Power Solution, Low Voltage, Smart Automation Solution, PLC, Smart Railway Solution, Signaling System and more
AMRS (Automatic Meter Reading System)
Meter reading center in a management office automatically and remotely reads electricity, gas, water, hot water, etc. usage meters installed in apartments or offices. The management office can conveniently retrieve and print the meter data without physically visiting the sites.
Features
Features
ㆍQuick and accurate meter measurements
ㆍEfficient meter management by providing various information using meter data
ㆍCheck meter reading data directly in each household through web services (When applying web services)
ㆍUp to 128 HCUM Management and Automatic Meter Reading
Function
ㆍMonthly, daily, and real-time trend graph display
ㆍMonitor total household daily/monthly usage
ㆍMonitor usage trend of individual household hourly/daily
ㆍSearching abnormal unit within a selected period
ㆍSave data in excel format
ㆍPrint data
Specifications
HCUM D/A (Home Control Unit Module)
ㆍCollect and provide data of remote unit measurement type electronic power and facility meters (gas, water, hot water, heating, cooling)
ㆍCollect data of electronic power and facility meters every minute or in real time and sending the meter data upon request of the SIU
ㆍCommunication method: RS-485 9,600bps (19,200, 38,400bps may be set)
ㆍSelf-diagnosis function through the internal LED (communication status, operation status, error status, etc.)
Rating | HCUM-D | HCUM-A |
---|---|---|
Rated voltage | DC12V (Supply from electricity meter) | |
Power consumption | Less than 2W | |
Mounting type | Wall mount type | |
Service temperature | -25℃ ~ 60℃ | |
Outage compensation (Pulse cognition) | - | 72 hours |
Battery fully charged | - | 48 hours |
Meter port | D-PLC port 2EA (Common) | Pulse cognition port 4EA |
Meter data | Electricity (forward and reverse active power), gas, water, hot water, heating, cooling | |
Communication port | RS-485 Port 1EA (Power Supply Cable, for remote type power meter) | |
RS-485 Port 2EA (Common circuit, for SIU / HCU communication) | ||
RS-485 Port 1EA (Spare, for EMS communication) | ||
Material | Body / Cover : Poly carbonate (White) | |
Size | 105(W) x 58(H) x 47(D) | |
Weight | 100g | 160g |
HCUM C (Home Control Unit Module-Compatible)
ㆍCollect and provide data from existing TTL type remote electronic power (transformer) and facility meters
ㆍCollect data of the electronic power meter and facility meters every minute and sends meter data upon request of the SIU
ㆍCommunication method: RS-485 9,600bps (19,200, 38,400bps can be set)
ㆍFully compatible with older CCU meter sites
Rating | HCUM-C(A4) | HCUM-C(AR) | HCUM-C(DS) | HCUM-C(DR) | HCUM-C(ON) | HCUM-C(OR) |
---|---|---|---|---|---|---|
Rated voltage | AC220V | |||||
Power consumption | Less than 3W | |||||
Mounting type | Wall mount type | |||||
Type | General type | General / Router type |
General type | General / Router type |
General type | General / Router type |
Service temperature | -25℃ ~ 60℃ | |||||
Outage compensation (Pulse cognition) | 72 hours | - | ||||
Battery fully charged | 48 hours | - | ||||
Meter port | Pulse: 4port | Pulse: 5port | DC-PLC: 2port (Common) | |||
Meter function | Pulse type analog meter | DC-PLC type digital meter | ||||
Open Collector pulse cognition | LS protocol (DS / Daesung) | Third Party Protocol (ON / Omni) | ||||
Meter data | Electricity, Gas, Water, Hot Water, Heating (All 5) | Electricity, Gas, Water, Hot Water, Heating, Cooling (6 types) | Electricity, Gas, Water, Hot Water, Heating (All 5) | |||
HCUM-C(AR) provides additional cooling meter (All 6) | ||||||
Communication type | SIU: RS-485 | SIU: RS-485 | ||||
Meter: Pulse cognition | Meter: DC-PLC | |||||
Communication distance | SIU: 1.2km (9,600bps, Shielded cable communication standards), Meter: Within 50m | |||||
Communication speed | SIU: 9,600bps | SIU: 9,600bps | ||||
Meter pulse cognition: >30msec | Meter: 2,400bps | Meter: 4,800bps | ||||
Material | Body / Cover : Poly carbonate (Gray / white) | |||||
Size | 44(W) x 108(H) x 56(D) | |||||
Weight | 260g ~ 280G |
SIU (Smart Interface Unit)
ㆍData bridge device between meter reading servers and meter reading devices
ㆍManage and operate up to 128 households of HCUMs per SIU
ㆍCommunication method: RS-485 9,600bps (19,200, 38,400bps can be set)
ㆍSelf-diagnosis function (communication status, data storage status, etc.)
Rating | Specification | |
---|---|---|
Rated voltage | 220VAC 60Hz±10% | |
Power consumption | 2W or less | |
Mounting type | Wall mount type (Screw & Din-rail) | |
Service temperature | -25℃ ~ 60℃ | |
Display | Power Status LED (On / Off) | Communication Status LED (Up / Down Link) |
Save meter data | 24 hours x 31 days x 128 HCUMs | |
Material | Poly carbonate (White) | |
Size | 40(W) x 107.5(H) x 55.5(D) | |
Weight | 130g |