Smart Power Solution, Low Voltage, Smart Automation Solution, PLC, Smart Railway Solution, Signaling System and more
L100 Elevator drive
L100 series offer best-in-class performance and size-optimized solutions for lifting applications. Optimized for lifting load operation, L100 series provide essential functions and options for elevator systems.
1. Compact Size reduction and performance enhancement by heat dissipation analysis and 3D design process Best-in-class performance and size-optimized solutions 5.5/7.5kW dimension • Half sized compared to other company products. |
|
2. Optimization Premium high performance vector control Available for various load conditions (control of both IM and PM) Smooth and precise control by optimized control algorithm (voltage/speed/flux control) Fast installation by optimized autotuning (PM/IM standstill auto-tune, IM rotational auto-tune) and easy control gain tuning Essential functions for elevator systems • Creepless |
|
3. Responsibility Built-in anti-noise EMC filter • 1st environment/category C2 (Class B) CE certificate
System stability with built-in safety (SIL 2)
|
|
4. Convenience Status LED for operation monitoring Easy keypad connection through front slide door Built-in dynamic brake circuit Removable terminal for easy maintenance DriveView9 support Built-in communication: CAN2.0B, RS-232C DC Reactor connector Easy cooling fan replacement |
Option
Incremental Encoder • Incremental A/B Pulse • Power: DC5/12/15V • Input: A+[PA], A-, B+[PB], B- • Output: RA, RB, RG (Encoder A, B phase return pulse) • Encoder: Line drive (5V), Open collector (12V, 15V) |
EnDat Encoder • HEIDENHAIN Encoder I/F (EnDat v2.2) • Power: DC5V • Input: SIN+, SIN-, COS+, COS-, DATA+, DATA-, CLK+, CLK- • Output: RA, RB, RG • Encoder: ECN413, ECN1313, ERN487, ERN1387 |
SIN/COS Encoder • HEIDENHAIN Encoder I/F • Power: DC5V • Input: SIN+, SIN-, COS+, COS-, SIN2+, SIN2-, COS2+, COS2- • Output: RA, RB, RG • Encoder: ECN413, ECN1313, ERN487, ERN1387 |
Elevator I/O (ELIO) • Dedicated to elevator I/O terminal • Digital input: 9 points for elevator car control • Digital output: 10 points for elevator car position and operation control • Fault information output: 4 points |
System Configuration
Basic Specification
LSLV[][][][]L100-4NNFN1) | 0055 | 0075 | 0110 | 0150 | 0185 | 0220 | |
---|---|---|---|---|---|---|---|
Max. motor capacity2) | [HP] | 7.5 | 10 | 15 | 20 | 25 | 30 |
[kW] | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | |
Rated output | Capacity | 9.1 | 12.2 | 18.3 | 22.9 | 29.7 | 34.3 |
Rated current [A] | 12 | 16 | 24 | 30 | 39 | 45 | |
Output speed | Induction motor: 0~3600[RPM], Synchronous motor: 0~680[RPM] | ||||||
Output voltage | 0 ~ 380 (480V)3) | ||||||
Rated input | Input voltage | 3-phase 380 ~ 480V (-10% ~ +10%) | |||||
Input frequency | 50 ~ 60Hz (±5%) | ||||||
Rated current [A] | 12.9 | 17.5 | 26.5 | 33.4 | 43.6 | 50.7 | |
Weight [kg (lbs)] | 3.3 (7.3) | 3.4 (7.5) | 4.6 (10.2) | 4.8 (10.6) | 7.5 (16.6) | 8.0 (17.7) |
1) Model name for LSLV-L100.
2) Standard motor capacity is based on a standard 440V 4-pole motor.
3) Maximum output voltage does not go over the supplied power voltage.
Dimension
Model Name | W1 | W2 | H1 | H2 | D1 | A | B | Weight [kg (Ibs)] |
---|---|---|---|---|---|---|---|---|
LSLV055L100-4 | 160 (6.30) |
137 (5.39) |
232 (9.13) |
217 (8.54) |
181 (7.16) |
5 (0.20) |
5 (0.20) |
3.3 (7.3) |
LSLV075L100-4 | 3.4 (7.5) | |||||||
LSLV110L100-4 | 180 (7.09) |
157 (6.18) |
290 (11.42) |
274 (10.79) |
205 (8.07) |
5 (0.20) |
5 (0.20) |
4.6 (10.2) |
LSLV150L100-4 | 4.8 (10.6) | |||||||
LSLV185L100-4 | 220 (8.66) |
194 (7.64) |
350 (13.78) |
331 (13.78) |
223 (8.78) |
6 (0.24) |
6 (0.24) |
7.5 (16.6) |
LSLV220L100-4 | 8.0 (17.7) |