Smart Power Solution, Low Voltage, Smart Automation Solution, PLC, Smart Railway Solution, Signaling System and more
EV Relay
The EV Relay GER series has a rated operating voltage of 450Vdc and has been proven to be reliable and stable, which can be applied to many eco-friendly projects of global automobiles in Korea and abroad.
Features
The Smallest Size Among Other Relays at the Same Performance Level
ㆍEnabling fabrication for minimum-sized panels
ㆍApplicable to diverse industries with low cost
Low Audible Noise & Anti-shock Design
ㆍSilent operation for environment comfort
ㆍReliable design to properly manage mechanical shock and vibrations
Superior Reliability Assurance Under Automotive Environment
ㆍSafe operation under volatile and harsh environments
ㆍExcellent performance with electrical and mechanical endurances
Specification
GER series(450Vdc)
Rating | |||||
---|---|---|---|---|---|
Model | GER010 | GER020 | GER040 | GER100 | |
Size, W x H x D(mm) | 56×45×28 | 56×45×28 | 67×47×35 | 81×70×39 | |
Contact | Short-time Current | 10A (continuously, 2mm2) | 20A (continuously 2.5mm²) | 40A (continuously, 10mm2) | 100A (continuously, 35mm2) |
(Over Current) | 15A (2min., 2mm2) | 30A (2min 2.5mm²) | 60A (15min., 10mm2) | 150A (15min., 35mm2) | |
30A (30sec., 2mm2) | 40A (15min 2.5mm²) | 100A (2min., 10mm2) | 225A (2min., 35mm2) | ||
Max. Cut-off Current | N / A | N / A | 400A at 450VDC (1cycle) | 1,000A at 450VDC (1cycle) | |
Reverse Direction Cut-off | N / A | N / A | -40A 200VDC (1,000 cycles at 20 CPM) |
-100A 200VDC (1,000 cycles at 20 CPM) |
|
Switch-off Life | N / A | N / A | 120A 450VDC (100 cycles) | 200A 450VDC (100 cycles) | |
Coil | Pick-up Voltage (at 20℃) |
Max. 9VDC | Max. 9VDC | Max. 9VDC, 18VDC | Max. 9VDC |
Drop-out Voltage (at 20℃) |
Min. 1.2VDC | Min. 1.2VDC | Min. 1.2VDC, 2.4VDC | Min. 1.2VDC | |
Max Power consumption | 3.0W (at 12VDC) | 3.0W (at 12VDC) | 3.5W (at 12VDC) | 6.5W (at 12VDC) | |
Expected life | Mechanical | Min. 150,000ops (at 60CPM) | Min. 150,000ops (at 60CPM) | Min. 200,000ops (at 60CPM) | Min. 200,000ops (at 60CPM) |
Electrical(Resistive Load) | 10A, 450VDC 150,000cycles (at 6CPM) (Only making) |
10A, 450VDC 150,000cycles (at 6CPM) (Only making) |
40A, 450VDC, 1,000cycles (at20CPM) |
100A, 450VDC, 1,000ops (at 20CPM) |
|
N / A | N / A | N / A | 40A, 450VDC, 20,000ops (at 20CPM) |
||
N / A | N / A | N / A | N / A |
GER(450VDC) | |||||
---|---|---|---|---|---|
Model | GER150 | GER200 | GER250 | GER400 | |
Size, W x H x D(mm) | 81×70×39 | 81×70×39 | 92×87×45 | 100×91×58 | |
Contact | Short-time Current | 150A (continuously, 50mm2) | 200A (contrnuously 50mm²) | 250A (continuously,100mm2) | 400A(continuously,150mm2) |
(Over Current) | 225A (15min., 50mm2) | 300A (2min 50mm²) | 350A (15min., 100mm2) | 600A (7min., 150mm2) | |
320A (2min., 50mm2) | 400A (500sec 50mm²) | 500A (2min., 100mm2) | 800A (2min., 150mm2) | ||
Max. Cut-off Current | 1,500A at 450VDC (1cycle) | 1,500A at 450VDC (1cycle) | 2,500A at 400VDC (1cycle) | 1,500A at 450VDC (1cycle) | |
Reverse Direction Cut-off | -150A 200VDC (500 cycles at 20 CPM) |
-150A 200VDC (500 cycles at 20 CPM) |
-250A 200VDC (1,000 cycles at 6 CPM) |
-400A 200VDC (1,000 cycles at 1 CPM) |
|
Switch-off Life | 300A 450VDC (100 cycles at 1 CPM) |
300A 450VDC (100 cycles at 1 CPM)
|
400A 450VDC (100 cycles at 1 CPM) |
800A 450VDC (200 cycles at 1 CPM) |
|
Coil | Pick-up Voltage (at 20℃) |
Max. 9VDC | Max. 8VDC | Max. 9VDC, 18VDC | Max. 9VDC, 16VDC |
Drop-out Voltage (at 20℃) |
Min. 1.2VDC | Min. 1.2VDC | Min. 1.2VDC, 2.4VDC | Min. 1.2VDC, 2.4VDC | |
Max Power consumption | 6.5W (at 12VDC) | 6.5W (at 12VDC) | 4W (*inrush current: 2.9/ 1.25A for 12/24V) |
4.5W (*inrush current: 4.2/ 2.1A for 12/24V) |
|
Expected life | Mechanical | Min. 200,000ops (at 60CPM) | Min. 200,000ops(at 60CPM) | Min. 200,000ops (at 60CPM) | Min. 200,000ops (at 60CPM) |
Electrical(Resistive Load) | 150A, 450VDC, 1,000ops (at 20CPM) |
200A 450V 1,000ops (at 6cpm) |
250A, 450VDC, 1,000ops (at 6CPM) |
400A, 450VDC, 1,000ops (at 6CPM) |
|
15A, 450VDC, 50,000ops (at 20CPM) |
240A 50V 75,000ops (at 6cpm) |
100A, 450VDC, 10,000ops (at 6CPM) |
200A, 450VDC, 3,000ops (at 12CPM) |
||
N / A | N / A | N / A | N / A |
GPR-M/GPR-H